Files
pumpingStation/test/_output-manifest.md
Rene De Ren 4889fdaaf0 docs(contract): close output-contract gaps — mode/manualDemand, Port-2 topic, output manifest
- wiki/Reference-Contracts.md: regenerate data-model (npm run wiki:all) so the
  two live getOutput() keys `mode` and `manualDemand` are documented; refresh
  stale sample values; bump code-ref badge -> a83a85e; add human note describing
  the two control-state keys.
- CONTRACT.md: fix Port-2 outgoing topic registerChild -> child.register
  (registerChild is the deprecated *input* alias, not what the node emits).
- test/_output-manifest.md: add the mandatory output manifest (Port 0/1/2 +
  emitter events + the 15-way fn_status_split fan-out) with honest coverage gaps.
- test/integration/basic-dashboard-flow.test.js: fix stale fan-out count 14->15
  (output 14 = percControl chart added upstream); assert out[14].

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-05-29 13:13:11 +02:00

102 lines
6.6 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# pumpingStation output manifest
> Single source of truth for **what this node emits and where it is tested**, per
> [`.claude/rules/output-coverage.md`](https://gitea.wbd-rd.nl/RnD/EVOLV/src/branch/development/.claude/rules/output-coverage.md).
> Generated against code-ref `a83a85e`. Regenerate the wiki contract with
> `npm run wiki:all` and re-check this table whenever `getOutput()`,
> `src/commands/index.js`, or an `examples/*.json` fan-out changes.
**Null convention for this node:** a Port-0 key whose source is not yet
available is emitted as **explicit `null`** (e.g. `timeleft`, `flowSource`,
`manualDemand` outside manual mode), never silently absent. Delta-compression on
Port 0 then drops keys whose value is unchanged since the previous tick.
## Port 0 (process data) — `specificClass.getOutput()` → `outputUtils.formatMsg(..., 'process')`
`msg.topic = config.general.name`. Keys below are the full pre-delta-compression set.
| Key | Source | Type | States tested | Test file |
|---|---|---|---|---|
| `mode` | `getOutput``this.mode` | string (`levelbased`/`manual`/`flowbased`/`none`) | populated (`manual`) | test/basic/specificClass.test.js |
| `manualDemand` | `getOutput``_manualDemand` | number m³/h, `null` outside manual | populated, null | test/basic/specificClass.test.js |
| `direction` | `getOutput``state.direction` | string (`filling`/`draining`/`steady`) | present | test/basic/specificClass.test.js |
| `flowSource` | `getOutput``state.flowSource` | string, `null` when no source | null (pre-child) | test/basic/specificClass.test.js |
| `timeleft` | `getOutput``state.seconds` | number s, `null` when steady | present, null | test/basic/specificClass.test.js |
| `percControl` | `getOutput``controlState.percControl` | number % 0..100 | 0, 25, 50, 75, 85, 100 | test/basic/specificClass.test.js |
| `dryRunLevel` | `_computeSafetyPoints` | number m | populated | test/basic/specificClass.test.js |
| `dryRunSafetyVol` | `_computeSafetyPoints` | number m³ | populated | test/basic/specificClass.test.js |
| `highVolumeSafetyLevel` | `_computeSafetyPoints` | number m | populated | test/basic/specificClass.test.js |
| `highVolumeSafetyVol` | `_computeSafetyPoints` | number m³ | populated | test/basic/specificClass.test.js |
| `predictedOverflowVolume` | `measurements` overflowVolume | number m³ | populated, 0 | test/basic/specificClass.test.js |
| `predictedOverflowRate` | `measurements` flow.overflow | number m³/s | populated, 0 | test/basic/specificClass.test.js |
| `predictedUnderflowVolume` | `measurements` underflowVolume | number m³ | 0 | test/basic/specificClass.test.js |
| `volume.predicted.atequipment.<childId>` | `measurements.getFlattenedOutput` | number m³ | populated | test/basic/specificClass.test.js |
| basin geometry: `heightBasin`, `surfaceArea`, `maxVol`, `minVol`, `maxVolAtOverflow`, `minVolAtInflow`, `minVolAtOutflow`, `volEmptyBasin`, `inflowLevel`, `outflowLevel`, `overflowLevel`, `inletPipeDiameter`, `outletPipeDiameter`, `minHeightBasedOn` | `basin.snapshot()` | number (m/m²/m³) / string | populated | test/basic/specificClass.test.js, test/basic/BasinGeometry.basic.test.js |
## Port 1 (InfluxDB telemetry) — `formatMsg(..., 'influxdb')`
Same key set as Port 0 (formatted via the `influxdb` formatter rather than
`process`). Field names == Port-0 keys; `config.general.name` is the measurement
tag. No Port-1-only fields. Covered transitively by the Port-0 tests above; a
dedicated Port-1 line-protocol assertion is a **gap** (see below).
## Port 2 (registration / control plumbing) — `BaseNodeAdapter._scheduleRegistration`
| Topic | Source | Payload shape | States tested | Test file |
|---|---|---|---|---|
| `child.register` | `BaseNodeAdapter.js:122` | `{ topic:'child.register', payload:<node.id>, positionVsParent, distance }` | — | _(gap — see below)_ |
> Note: the canonical outgoing topic is **`child.register`** (matching the input
> registry). Earlier docs said `registerChild`; that is the deprecated input
> alias, not what this node emits.
## Child-facing events — `measurements.emitter`
Fired as `<type>.<variant>.<position>` when a series receives a value. Parents
subscribe by event name (data-driven, not a fixed catalogue):
| Event | When | Test file |
|---|---|---|
| `volume.predicted.atequipment` | each integrator tick | test/basic/flowAggregator.basic.test.js |
| `level.predicted.atequipment` | recomputed from volume | test/basic/specificClass.test.js |
| `flow.predicted.in` (child `manual-qin`) | `set.inflow` handler | test/basic/measurementRouter.basic.test.js |
| `overflowVolume`/`underflowVolume`/`flow.predicted.overflow` | integrator hits a physical bound | test/basic/flowAggregator.basic.test.js |
## Example-flow function-node fan-out
### examples/02-Dashboard.json :: `fn_status_split` (outputs: 15)
| # | Target widget | Payload | Populated | Degraded/null |
|---|---|---|---|---|
| 0 | ui-text "Mode" | string | ✔ structure | gap |
| 1 | ui-text "Direction" | string | ✔ | gap |
| 2 | ui-text "Level" | number m | ✔ | gap |
| 3 | ui-text "Volume" | number m³ | ✔ | gap |
| 4 | ui-text "Volume %" | number % | ✔ | gap |
| 5 | ui-text "percControl" | number % | ✔ | gap |
| 6 | ui-text "Manual demand" | number m³/h or — | gap | gap |
| 7 | ui-chart "Level (m)" | `{topic,payload:number}` or no-msg | ✔ | gap |
| 8 | ui-chart "Volume (m³)" | ″ | ✔ | gap |
| 9 | ui-chart "Volume %" | ″ | ✔ | gap |
| 10 | ui-chart "Flow (m³/h)" — Inflow | ″ | ✔ | gap |
| 11 | ui-chart "Flow (m³/h)" — Outflow | ″ | ✔ | gap |
| 12 | ui-chart "Flow (m³/h)" — Net | ″ | ✔ | gap |
| 13 | ui-template "Raw output table" | whole object (array) | ✔ | gap |
| 14 | ui-chart "percControl" | `{topic:'percControl',payload:number}` | ✔ | gap |
Populated/structure coverage: test/integration/basic-dashboard-flow.test.js
(asserts output count = 15 and routes outputs 014). **Degraded/empty-input**
coverage (no `payload:null` reaching any `ui-chart`) is still a gap — see below.
## Known coverage gaps (tracked, prospective per the rule)
The output-coverage rule applies prospectively. Outstanding items for this node:
- [ ] Dedicated `test/basic/output-port0.test.js` exercising **every** key above
in both populated and degraded (pre-tick / null) states.
- [ ] Port-1 line-protocol assertion (field names + tag).
- [ ] Port-2 `child.register` payload-shape test.
- [ ] `fn_status_split` degraded/empty-input fan-out test (no `payload:null` to
any `ui-chart`) — the failure mode the rule was written for. The structure