New standard, pilot pass for pumpingStation. Sets the pattern the other 10 nodes will follow once we sign off on this one. Zone A (wiki/Home.md, ~180 lines): - one-sentence opener - "at a glance" 5-row fact table - "How it looks in Node-RED" — screenshot placeholder - "What it models" — embeds the existing basin-model.drawio.svg - "Try it" — 3-minute demo with curl-load command, click list, GIF placeholder - "Typical wiring" — two placeholder screenshots (standalone + integrated), no mermaid (per user direction) - "The five things you'll send" + sample Port-0 payload table - "Need more?" footer linking to Reference-* siblings Zone B (4 sibling pages): - Reference-Contracts.md — full topic contract + data model (AUTOGEN markers); config schema; child registration filters; unit policy - Reference-Architecture.md — 3-tier code layout; safety FSM (stateDiagram-v2); tick lifecycle (sequenceDiagram); output ports - Reference-Examples.md — 01-Basic / 02-Integration / 03-Dashboard walk-through with per-example screenshot + GIF placeholders; debug-recipes table - Reference-Limitations.md — implemented vs schema-only modes; basin-shape constraint; net-flow source caveat; alias-removal map Asset directory placeholders created: - wiki/_partial-screenshots/pumpingStation/.gitkeep - wiki/_partial-gifs/pumpingStation/.gitkeep - wiki/_partial-flows/pumpingStation/.gitkeep Abandoned per user direction (no longer linked, removed from source): - wiki/README.md - wiki/functional-description.md (377 lines retired) - wiki/modes/*.md (5 files retired) Diagrams kept in place (wiki/diagrams/*.drawio.svg) — referenced from Home and Reference-Architecture. package.json: wiki:contract + wiki:datamodel now target Reference-Contracts.md instead of Home.md. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
165 lines
8.6 KiB
Markdown
165 lines
8.6 KiB
Markdown
# Reference — Contracts
|
|
|
|
 
|
|
|
|
> [!NOTE]
|
|
> Full topic contract, configuration schema, and child-registration filters for `pumpingStation`. The topic-contract and data-model sections are **regenerated by `npm run wiki:all`** — do not hand-edit between the `BEGIN AUTOGEN` / `END AUTOGEN` markers. Source of truth for everything on this page: the node's `src/commands/index.js`, `src/specificClass.js` `configure()`, and the schema at `generalFunctions/src/configs/pumpingStation.json`.
|
|
>
|
|
> For an intuitive overview, return to the [Home](Home).
|
|
|
|
---
|
|
|
|
## Topic contract
|
|
|
|
The **Unit** column reflects each descriptor's `units: { measure, default }` declaration. The default unit is what the commandRegistry coerces incoming `msg.unit` values to before the handler runs.
|
|
|
|
<!-- BEGIN AUTOGEN: topic-contract -->
|
|
|
|
| Canonical topic | Aliases | Payload | Unit | Effect |
|
|
|---|---|---|---|---|
|
|
| `set.mode` | `changemode` | `string` | — | Switch the station between auto / manual control modes. |
|
|
| `child.register` | `registerChild` | `string` | — | Register a child node (machine group, measurement, …) with this station. |
|
|
| `cmd.calibrate.volume` | `calibratePredictedVolume` | `any` | `volume` (default `m3`) | Calibrate the predicted-volume integrator to a known basin volume. |
|
|
| `cmd.calibrate.level` | `calibratePredictedLevel` | `any` | `length` (default `m`) | Calibrate the predicted-volume integrator to a known basin level. |
|
|
| `set.inflow` | `q_in` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured inflow value into the basin balance. |
|
|
| `set.outflow` | `q_out` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured outflow value into the basin balance. |
|
|
| `set.demand` | `Qd` | `any` | `volumeFlowRate` (default `m3/h`) | Operator outflow demand setpoint for the station. |
|
|
|
|
<!-- END AUTOGEN: topic-contract -->
|
|
|
|
---
|
|
|
|
## Data model — `getOutput()` shape
|
|
|
|
Keys composed each tick by `specificClass.getOutput()` and emitted via `outputUtils.formatMsg` on Port 0. Delta-compressed: consumers see only the keys that changed.
|
|
|
|
<!-- BEGIN AUTOGEN: data-model -->
|
|
|
|
| Key | Type | Unit | Sample |
|
|
|---|---|---|---|
|
|
| `direction` | string | — | `"steady"` |
|
|
| `dryRunLevel` | number | — | `0.20400000000000001` |
|
|
| `dryRunSafetyVol` | number | — | `0.20400000000000001` |
|
|
| `flowSource` | null | — | `null` |
|
|
| `heightBasin` | number | m | `1` |
|
|
| `highVolumeSafetyLevel` | number | — | `2.45` |
|
|
| `highVolumeSafetyVol` | number | — | `2.45` |
|
|
| `inflowLevel` | number | m | `2` |
|
|
| `inletPipeDiameter` | number | — | `0.4` |
|
|
| `maxVol` | number | m3 | `1` |
|
|
| `maxVolAtOverflow` | number | m3 | `2.5` |
|
|
| `minHeightBasedOn` | string | — | `"outlet"` |
|
|
| `minVol` | number | m3 | `0.2` |
|
|
| `minVolAtInflow` | number | m3 | `2` |
|
|
| `minVolAtOutflow` | number | m3 | `0.2` |
|
|
| `outflowLevel` | number | m | `0.2` |
|
|
| `outletPipeDiameter` | number | — | `0.4` |
|
|
| `overflowLevel` | number | m | `2.5` |
|
|
| `percControl` | number | % | `0` |
|
|
| `predictedOverflowRate` | number | — | `0` |
|
|
| `predictedOverflowVolume` | number | — | `0` |
|
|
| `predictedUnderflowVolume` | number | — | `0` |
|
|
| `surfaceArea` | number | m2 | `1` |
|
|
| `timeleft` | null | s | `null` |
|
|
| `volEmptyBasin` | number | m3 | `1` |
|
|
| `volume.predicted.atequipment.wikigen-pumpingstation-id` | number | m3 | `0.2` |
|
|
|
|
<!-- END AUTOGEN: data-model -->
|
|
|
|
Sample values come from a stub instantiation in `wikiGen` — in a live deployment the volume key is shaped `volume.<variant>.<position>.<childId>` per the standard [Measurement Key Shape](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions#measurement-key-shape).
|
|
|
|
---
|
|
|
|
## Configuration schema — editor form to config keys
|
|
|
|
Source of truth: `generalFunctions/src/configs/pumpingStation.json`.
|
|
|
|
### Basin geometry (`config.basin`)
|
|
|
|
| Form field | Config key | Default | Unit | Notes |
|
|
|:---|:---|:---|:---|:---|
|
|
| Basin Volume | `basin.volume` | `1` | m3 | Total geometric storage from floor to rim |
|
|
| Basin Height | `basin.height` | `1` | m | Floor-to-rim wall height |
|
|
| Inlet Elevation | `basin.inflowLevel` | `2` | m | Bottom of incoming pipe, from floor |
|
|
| Outlet Elevation | `basin.outflowLevel` | `0.2` | m | Top of pump-suction pipe, from floor |
|
|
| Inlet Pipe Diameter | `basin.inletPipeDiameter` | `0.4` | m | For future hydraulic upgrades |
|
|
| Outlet Pipe Diameter | `basin.outletPipeDiameter` | `0.4` | m | For future hydraulic upgrades |
|
|
| Overflow Level | `basin.overflowLevel` | `2.5` | m | Physical overflow weir crest |
|
|
|
|
### Safety thresholds (`config.safety`)
|
|
|
|
| Form field | Config key | Default | Notes |
|
|
|:---|:---|:---|:---|
|
|
| High-Volume Safety % | `safety.highVolumeSafetyThresholdPercent` | `98` | Trigger high-volume safety at this fill % |
|
|
| Dry-Run Safety Level | `safety.dryRunLevel` | `0.2` | Below this level all pumps stop |
|
|
| Enable High-Volume Safety | `safety.enableHighVolumeSafety` | `true` | Master switch |
|
|
|
|
> [!WARNING]
|
|
> Earlier versions used `enableOverfillProtection` and `overfillThresholdPercent`. Those names are deprecated. The current canonical names are `enableHighVolumeSafety` and `highVolumeSafetyThresholdPercent`. See `.claude/refactor/OPEN_QUESTIONS.md` for the alias-removal timeline.
|
|
|
|
### Control mode (`config.control`)
|
|
|
|
| Form field | Config key | Default | Notes |
|
|
|:---|:---|:---|:---|
|
|
| Mode | `control.mode` | `"levelbased"` | One of `levelbased`, `manual`, `flowbased`*, `pressureBased`*, `percentageBased`*, `powerBased`*, `hybrid`*. Asterisked modes are placeholders in code. |
|
|
| Level Curve Type | `control.levelbased.curveType` | `"linear"` | `linear` or `log` |
|
|
| Log Curve Factor | `control.levelbased.logCurveFactor` | `0.5` | Slope tuning for log curve |
|
|
| Min Level | `control.levelbased.minLevel` | `0.3` | Demand hard-zero below this |
|
|
| Start Level | `control.levelbased.startLevel` | `0.5` | Falling-ramp returns to 0 % here |
|
|
| Stop Level | `control.levelbased.stopLevel` | `0.4` | Schmitt-trigger lower bound for pump-count keep-alive |
|
|
| Max Level | `control.levelbased.maxLevel` | `2.3` | Demand saturates at 100 % here |
|
|
| Enable Shifted Ramp | `control.levelbased.enableShiftedRamp` | `true` | Hysteresis-armed shift between rising / falling ramps |
|
|
| Manual Flow Setpoint | `control.manual.flowSetpoint` | `0` | Honoured in `manual` mode |
|
|
|
|
### General (`config.general`)
|
|
|
|
| Form field | Config key | Default | Notes |
|
|
|:---|:---|:---|:---|
|
|
| Time-left full / empty threshold | `general.timeleftToFullOrEmptyThresholdSeconds` | `120` | ETA below this triggers warning state |
|
|
| Flow dead-band | `general.flowThreshold` | `1e-4` m³/s | Net-flow below this is treated as steady |
|
|
|
|
---
|
|
|
|
## Child registration
|
|
|
|
Source: `nodes/pumpingStation/src/specificClass.js` `configure()`, lines 107–116.
|
|
|
|
| Software type | Filter | Wired to | Side-effect |
|
|
|:---|:---|:---|:---|
|
|
| `measurement` | any | `_subscribeMeasurement` | Subscribes to the measurement's emitter; updates basin balance |
|
|
| `machine` | only if no `machinegroup` parent is present | direct dispatch | Bypassed when an MGC is the predicted-flow source |
|
|
| `machinegroup` | any | `_subscribePredictedFlow` | Reads aggregated predicted flow from the MGC |
|
|
| `pumpingstation` | any | `_subscribePredictedFlow` | Cascaded PS — reads predicted outflow of upstream station |
|
|
|
|
The router only subscribes to the **highest-level aggregator** for predicted flow. If an MGC is present, direct `machine` children are not double-counted.
|
|
|
|
---
|
|
|
|
## Unit policy
|
|
|
|
Source: `nodes/pumpingStation/src/specificClass.js` lines 21–30.
|
|
|
|
| Quantity | Canonical (internal) | Output (rendered) |
|
|
|:---|:---|:---|
|
|
| Flow | `m3/s` | `m3/s` (also `netFlowRate`) |
|
|
| Level | `m` | `m` |
|
|
| Volume | `m3` | `m3` |
|
|
| Pressure | `Pa` | (not surfaced) |
|
|
| Power | `W` | (not surfaced) |
|
|
| Temperature | `K` | (not surfaced) |
|
|
|
|
`overflowVolume` and `underflowVolume` are explicitly listed in the policy output so the `MeasurementContainer` keeps the integrator's `m3` unit on those streams (`FlowAggregator` writes spill / underflow per tick).
|
|
|
|
---
|
|
|
|
## Related pages
|
|
|
|
| Page | Why |
|
|
|:---|:---|
|
|
| [Home](Home) | Intuitive overview |
|
|
| [Reference — Architecture](Reference-Architecture) | Code map, state chart, lifecycle |
|
|
| [Reference — Examples](Reference-Examples) | Shipped example flows |
|
|
| [Reference — Limitations](Reference-Limitations) | Known limitations and open questions |
|
|
| [EVOLV — Topic Conventions](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions) | Platform-wide topic rules |
|
|
| [EVOLV — Telemetry](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Telemetry) | Port 0 / 1 / 2 InfluxDB layout |
|