docs(contract): close output-contract gaps — mode/manualDemand, Port-2 topic, output manifest

- wiki/Reference-Contracts.md: regenerate data-model (npm run wiki:all) so the
  two live getOutput() keys `mode` and `manualDemand` are documented; refresh
  stale sample values; bump code-ref badge -> a83a85e; add human note describing
  the two control-state keys.
- CONTRACT.md: fix Port-2 outgoing topic registerChild -> child.register
  (registerChild is the deprecated *input* alias, not what the node emits).
- test/_output-manifest.md: add the mandatory output manifest (Port 0/1/2 +
  emitter events + the 15-way fn_status_split fan-out) with honest coverage gaps.
- test/integration/basic-dashboard-flow.test.js: fix stale fan-out count 14->15
  (output 14 = percControl chart added upstream); assert out[14].

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
Rene De Ren
2026-05-29 13:10:43 +02:00
parent a83a85e958
commit 4889fdaaf0
4 changed files with 134 additions and 24 deletions

View File

@@ -1,6 +1,6 @@
# Reference &mdash; Contracts
![code-ref](https://img.shields.io/badge/code--ref-b825ac1-blue) ![autogen](https://img.shields.io/badge/sections-autogenerated-orange)
![code-ref](https://img.shields.io/badge/code--ref-a83a85e-blue) ![autogen](https://img.shields.io/badge/sections-autogenerated-orange)
> [!NOTE]
> Full topic contract, configuration schema, and child-registration filters for `pumpingStation`. The topic-contract and data-model sections are **regenerated by `npm run wiki:all`** &mdash; do not hand-edit between the `BEGIN AUTOGEN` / `END AUTOGEN` markers. Source of truth for everything on this page: the node's `src/commands/index.js`, `src/specificClass.js` `configure()`, and the schema at `generalFunctions/src/configs/pumpingStation.json`.
@@ -19,11 +19,11 @@ The **Unit** column reflects each descriptor's `units: { measure, default }` dec
|---|---|---|---|---|
| `set.mode` | `changemode` | `string` | — | Switch the station between auto / manual control modes. |
| `child.register` | `registerChild` | `string` | — | Register a child node (machine group, measurement, …) with this station. |
| `cmd.calibrate.volume` | `calibratePredictedVolume` | any | `volume` (default `m3`) | Calibrate the predicted-volume integrator to a known basin volume. |
| `cmd.calibrate.level` | `calibratePredictedLevel` | any | `length` (default `m`) | Calibrate the predicted-volume integrator to a known basin level. |
| `set.inflow` | `q_in` | any | `volumeFlowRate` (default `m3/h`) | Push a measured inflow value into the basin balance. |
| `set.outflow` | `q_out` | any | `volumeFlowRate` (default `m3/h`) | Push a measured outflow value into the basin balance. |
| `set.demand` | `Qd` | any | `volumeFlowRate` (default `m3/h`) | Operator outflow demand setpoint for the station. |
| `cmd.calibrate.volume` | `calibratePredictedVolume` | `any` | `volume` (default `m3`) | Calibrate the predicted-volume integrator to a known basin volume. |
| `cmd.calibrate.level` | `calibratePredictedLevel` | `any` | `length` (default `m`) | Calibrate the predicted-volume integrator to a known basin level. |
| `set.inflow` | `q_in` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured inflow value into the basin balance. |
| `set.outflow` | `q_out` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured outflow value into the basin balance. |
| `set.demand` | `Qd` | `any` | `volumeFlowRate` (default `m3/h`) | Operator outflow demand setpoint for the station. |
<!-- END AUTOGEN: topic-contract -->
@@ -39,35 +39,42 @@ Keys composed each tick by `specificClass.getOutput()` and emitted via `outputUt
|---|---|---|---|
| `direction` | string | — | `"steady"` |
| `dryRunLevel` | number | — | `0.20400000000000001` |
| `dryRunSafetyVol` | number | — | `0.20400000000000001` |
| `dryRunSafetyVol` | number | — | `2.55` |
| `flowSource` | null | — | `null` |
| `heightBasin` | number | m | `1` |
| `highVolumeSafetyLevel` | number | — | `2.45` |
| `highVolumeSafetyVol` | number | — | `2.45` |
| `inflowLevel` | number | m | `2` |
| `heightBasin` | number | m | `4` |
| `highVolumeSafetyLevel` | number | — | `3.7239999999999998` |
| `highVolumeSafetyVol` | number | — | `46.55` |
| `inflowLevel` | number | m | `1.5` |
| `inletPipeDiameter` | number | — | `0.4` |
| `maxVol` | number | m3 | `1` |
| `maxVolAtOverflow` | number | m3 | `2.5` |
| `manualDemand` | null | | `null` |
| `maxVol` | number | m3 | `50` |
| `maxVolAtOverflow` | number | m3 | `47.5` |
| `minHeightBasedOn` | string | — | `"outlet"` |
| `minVol` | number | m3 | `0.2` |
| `minVolAtInflow` | number | m3 | `2` |
| `minVolAtOutflow` | number | m3 | `0.2` |
| `minVol` | number | m3 | `2.5` |
| `minVolAtInflow` | number | m3 | `18.75` |
| `minVolAtOutflow` | number | m3 | `2.5` |
| `mode` | string | — | `"levelbased"` |
| `outflowLevel` | number | m | `0.2` |
| `outletPipeDiameter` | number | — | `0.4` |
| `overflowLevel` | number | m | `2.5` |
| `overflowLevel` | number | m | `3.8` |
| `percControl` | number | % | `0` |
| `predictedOverflowRate` | number | — | `0` |
| `predictedOverflowVolume` | number | — | `0` |
| `predictedUnderflowVolume` | number | — | `0` |
| `surfaceArea` | number | m2 | `1` |
| `surfaceArea` | number | m2 | `12.5` |
| `timeleft` | null | s | `null` |
| `volEmptyBasin` | number | m3 | `1` |
| `volume.predicted.atequipment.wikigen-pumpingstation-id` | number | m3 | `0.2` |
| `volEmptyBasin` | number | m3 | `50` |
| `volume.predicted.atequipment.wikigen-pumpingstation-id` | number | m3 | `2.5` |
<!-- END AUTOGEN: data-model -->
Sample values come from a stub instantiation in `wikiGen` &mdash; in a live deployment the volume key is shaped `volume.<variant>.<position>.<childId>` per the standard [Measurement Key Shape](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions#measurement-key-shape).
> [!NOTE]
> Two control-state keys carry the live operating mode rather than a measurement:
> - `mode` &mdash; string, the active control strategy (`levelbased` / `manual` / `flowbased` / `none`). Echoes the most recent `set.mode` input.
> - `manualDemand` &mdash; number (m³/h) or `null`. The operator outflow setpoint last accepted via `set.demand`; `null` outside `manual` mode.
---
## Configuration schema &mdash; editor form to config keys