P6.4 follow-up: diffuser config schema additions
The P6.4 diffuser refactor reads headerPressure, localAtmPressure, waterDensity, and zoneVolume out of the config. validateSchema strips unknown keys, so without these definitions the values fell out of the config object before specificClass could read them. Added with sensible defaults that match the pre-refactor inline constants. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -106,6 +106,34 @@
|
|||||||
"type": "number",
|
"type": "number",
|
||||||
"description": "Alpha factor used for oxygen transfer correction."
|
"description": "Alpha factor used for oxygen transfer correction."
|
||||||
}
|
}
|
||||||
|
},
|
||||||
|
"headerPressure": {
|
||||||
|
"default": 0,
|
||||||
|
"rules": {
|
||||||
|
"type": "number",
|
||||||
|
"description": "Header gauge pressure above atmospheric (mbar)."
|
||||||
|
}
|
||||||
|
},
|
||||||
|
"localAtmPressure": {
|
||||||
|
"default": 1013.25,
|
||||||
|
"rules": {
|
||||||
|
"type": "number",
|
||||||
|
"description": "Local atmospheric pressure (mbar)."
|
||||||
|
}
|
||||||
|
},
|
||||||
|
"waterDensity": {
|
||||||
|
"default": 997,
|
||||||
|
"rules": {
|
||||||
|
"type": "number",
|
||||||
|
"description": "Water density used in head-pressure calculation (kg/m3)."
|
||||||
|
}
|
||||||
|
},
|
||||||
|
"zoneVolume": {
|
||||||
|
"default": 0,
|
||||||
|
"rules": {
|
||||||
|
"type": "number",
|
||||||
|
"description": "Aeration zone volume used to convert oxygen output to reactor OTR (m3)."
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
Reference in New Issue