Bump pumpingStation@8a6ca1b + generalFunctions@35f648f
Some checks failed
CI / lint-and-test (push) Has been cancelled

- pumpingStation: level-armed shift hysteresis, derived dryRunLevel,
  side-panel editor with hover-coupling, manual q_out for end-to-end
  testing without rotating-machine wiring.
- generalFunctions: schema additions for flowThreshold, output formats,
  enableShiftedRamp / shiftLevel under control.levelbased.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Rene De Ren
2026-05-05 19:29:49 +02:00
parent 2593458bdf
commit 7c6c6183f7
2 changed files with 2 additions and 2 deletions