Bump rotatingMachine + machineGroupControl submodule pointers
Some checks failed
CI / lint-and-test (push) Has been cancelled

- rotatingMachine@399e0a8: editor hygiene (name default, status
  clear on close), remove redundant idle-position clamp in
  flow/power predictions.
- machineGroupControl@9c79dac: bug fix — stale flow/power cache
  now cleared on MGC shutdown so parent pumpingStation sees the
  drop immediately. Also awaits shutdown promises correctly and
  corrects the NCog integration tests to match centrifugal-pump
  physics (Q/P monotonic → NCog=0 → fallback to equal distribution).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
znetsixe
2026-04-22 17:51:25 +02:00
parent d22d1cabd1
commit 33ac527274
2 changed files with 2 additions and 2 deletions