167b1026f1 docs(CONTRACT): document valve's lack of a maintenance state machine
valve's schema mode enum includes `maintenance` (which gates sources)
but the FSM has no `entermaintenance` / `exitmaintenance` states and
the schema's `sequences` block has only startup / shutdown /
emergencystop / boot. Maintenance mode therefore disables external
sources but doesn't run a maintenance sequence — different shape
from rotatingMachine. Added a Limitations section to the CONTRACT so
this is explicit rather than surfacing as a wiki TODO.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-19 16:35:28 +02:00

View File

@@ -68,6 +68,18 @@ from the measurement container (e.g. `delta_predicted_pressure`,
(`idle → starting → warmingup → operational → accelerating →
decelerating → stopping → coolingdown → idle`, plus `off`).
## Limitations vs `rotatingMachine`
- **No `maintenance` state machine.** The schema's `mode.current` enum
accepts `maintenance` (gates sources via `isValidSourceForMode`), but
the FSM has no `entermaintenance` / `exitmaintenance` states and the
`sequences` schema declares only `startup`, `shutdown`, `emergencystop`,
and `boot`. Configuring `maintenance` mode therefore disables external
command sources but does not put the valve through a maintenance
sequence. Aligns with valve's role as a passive flow-controlled
actuator; lift to RM-style FSM if/when site maintenance procedures
require explicit state transitions.