Add "Home"
109
Home.md
Normal file
109
Home.md
Normal file
@@ -0,0 +1,109 @@
|
||||
# rotatingMachine
|
||||
|
||||
Custom Node-RED node for modeling and controlling individual rotating equipment: pumps, compressors, and blowers.
|
||||
|
||||
## Overview
|
||||
|
||||
| Property | Value |
|
||||
|----------|-------|
|
||||
| **Version** | 1.0.3 |
|
||||
| **Category** | Process Control |
|
||||
| **Inputs** | 1 |
|
||||
| **Outputs** | 3 (process / dbase / parent) |
|
||||
| **Part of** | [EVOLV](https://gitea.wbd-rd.nl/RnD/EVOLV) |
|
||||
|
||||
## Purpose
|
||||
|
||||
The `rotatingMachine` node represents a single piece of rotating equipment (pump, compressor, or blower). It models:
|
||||
|
||||
- **Speed control** with static or dynamic setpoints
|
||||
- **Startup/shutdown sequences** with warmup and cooldown phases
|
||||
- **Pump curve interpolation** for flow, pressure, and power relationships
|
||||
- **State management** (off, starting, running, stopping, cooldown)
|
||||
|
||||
## Configuration
|
||||
|
||||
### Control
|
||||
|
||||
| Field | Description | Default |
|
||||
|-------|-------------|---------|
|
||||
| `speed` | Speed setpoint | - |
|
||||
| Movement mode | `staticspeed` (fixed) or `dynspeed` (variable) | staticspeed |
|
||||
| `startup` | Time to reach operating speed (s) | - |
|
||||
| `warmup` | Warmup hold time after startup (s) | - |
|
||||
| `shutdown` | Time to ramp down (s) | - |
|
||||
| `cooldown` | Cooldown hold time after shutdown (s) | - |
|
||||
|
||||
### Curve Units
|
||||
|
||||
| Field | Description | Default |
|
||||
|-------|-------------|---------|
|
||||
| `curvePressureUnit` | Pressure unit for curves | mbar |
|
||||
| `curveFlowUnit` | Flow unit for curves | - |
|
||||
| `curvePowerUnit` | Power unit for curves | kW |
|
||||
| `curveControlUnit` | Control signal unit | % |
|
||||
|
||||
### Asset Identification
|
||||
|
||||
| Field | Description |
|
||||
|-------|-------------|
|
||||
| `uuid` | Unique asset identifier |
|
||||
| `supplier` | Equipment manufacturer |
|
||||
| `category` | Equipment category |
|
||||
| `assetType` | Asset type classification |
|
||||
| `model` | Equipment model |
|
||||
|
||||
### Logging
|
||||
|
||||
| Field | Description | Default |
|
||||
|-------|-------------|---------|
|
||||
| `enableLog` | Enable node logging | false |
|
||||
| `logLevel` | Log verbosity level | - |
|
||||
|
||||
## Inputs and Outputs
|
||||
|
||||
### Input (Port 0)
|
||||
|
||||
Accepts `msg.payload` with control commands:
|
||||
- Speed setpoints
|
||||
- Start/stop commands
|
||||
- Configuration updates
|
||||
|
||||
### Output Port 0 - Process Data
|
||||
|
||||
Current machine state including:
|
||||
- Operating speed, flow, pressure, power
|
||||
- Machine state (off/starting/running/stopping/cooldown)
|
||||
- Calculated efficiency
|
||||
|
||||
### Output Port 1 - InfluxDB Telemetry
|
||||
|
||||
Time-series data formatted for InfluxDB ingestion.
|
||||
|
||||
### Output Port 2 - Registration
|
||||
|
||||
Parent-child communication messages for registration with `machineGroupControl` or `pumpingStation`.
|
||||
|
||||
## Parent Nodes
|
||||
|
||||
This node can be a child of:
|
||||
- **[machineGroupControl](https://gitea.wbd-rd.nl/RnD/machineGroupControl)** - For coordinated group operation
|
||||
- **[pumpingStation](https://gitea.wbd-rd.nl/RnD/pumpingStation)** - For hydraulic optimization context
|
||||
|
||||
## Dependencies
|
||||
|
||||
- [generalFunctions](https://gitea.wbd-rd.nl/RnD/generalFunctions) (MenuManager, configManager, asset utilities)
|
||||
|
||||
## Technical Requirements
|
||||
|
||||
- Node.js >= 18
|
||||
- Node-RED >= 3.x
|
||||
- Parent EVOLV package installed
|
||||
|
||||
## Testing
|
||||
|
||||
```bash
|
||||
node --test test/basic/*.test.js
|
||||
node --test test/integration/*.test.js
|
||||
node --test test/edge/*.test.js
|
||||
```
|
||||
Reference in New Issue
Block a user