Files
rotatingMachine/test/basic/nodeClass-config.basic.test.js
znetsixe e058fe9245 P5 wave 2: convert rotatingMachine to BaseDomain + extract helper modules
specificClass.js: 1760 → 400 lines.
  Machine extends BaseDomain. configure() wires curves + predictors +
  drift + pressure + state bindings + measurement handlers + flow
  controller. ChildRouter handles pressure/flow/power/temperature
  measurement events; custom registerChild override preserves the
  dedup + virtual-vs-real pressure tracking the integration tests
  pin.

  Added small host-aware helper modules to fit the 400-line cap:
    src/prediction/predictionMath.js   (calcFlow/Power/Ctrl)
    src/prediction/efficiencyMath.js   (calcCog/EfficiencyCurve/etc.)
    src/pressure/pressureSelector.js   (getMeasuredPressure source preference)
    src/state/sequenceController.js    (executeSequence/setpoint/wait helpers)
    src/measurement/childRegistrar.js  (custom registerChild path)
    src/drift/healthRefresh.js         (drift status update wrappers)
    src/io/output.js                   (buildOutput + buildStatusBadge)

  unitPolicy: live UnitPolicy methods .canonical()/.output()/.curve()
  bridged to legacy property-path readers via a frozen view object —
  same pattern as MGC. See OPEN_QUESTIONS.md.

nodeClass.js: 433 → 61 lines.
  Extends BaseNodeAdapter. tickInterval=null (event-driven on state +
  measurement events). buildDomainConfig stamps the rotatingMachine
  state + errorMetrics slices on the domain config so configure()
  builds them from there.

5 tests adjusted (4 nodeClass-config, 1 error-paths) — pre-refactor
they pinned private methods (_loadConfig, _setupSpecificClass,
_attachInputHandler, _updateNodeStatus) that no longer exist. New
versions drive the public BaseNodeAdapter surface or call extracted
io/state-machine helpers directly. See OPEN_QUESTIONS.md 2026-05-10
"private nodeClass tests" for the deferred rewrite plan.

196 / 196 tests pass (basic 110 + integration ~80 + edge ~6).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-10 22:00:34 +02:00

87 lines
3.2 KiB
JavaScript

const test = require('node:test');
const assert = require('node:assert/strict');
const NodeClass = require('../../src/nodeClass');
const Machine = require('../../src/specificClass');
const { makeNodeStub } = require('../helpers/factories');
// After the BaseNodeAdapter migration, _loadConfig + _setupSpecificClass
// are gone — config building lives in buildDomainConfig(). These tests
// drive that contract through a prototype-derived nodeClass instance so
// we exercise the surface without booting Node-RED.
function makeUiConfig(overrides = {}) {
return {
unit: 'm3/h',
enableLog: false,
logLevel: 'error',
supplier: 'hidrostal',
category: 'machine',
assetType: 'pump',
model: 'hidrostal-H05K-S03R',
curvePressureUnit: 'mbar',
curveFlowUnit: 'm3/h',
curvePowerUnit: 'kW',
curveControlUnit: '%',
positionVsParent: 'atEquipment',
speed: 1,
movementMode: 'staticspeed',
startup: 0,
warmup: 0,
shutdown: 0,
cooldown: 0,
...overrides,
};
}
function callBuildDomainConfig(ui) {
const inst = Object.create(NodeClass.prototype);
// Clear any leftover pending extras so this test's call is the only one
// that stamps Machine._pendingExtras.
Machine._pendingExtras = null;
return inst.buildDomainConfig(ui);
}
test('buildDomainConfig maps legacy editor fields for asset identity', () => {
const cfg = callBuildDomainConfig(makeUiConfig({ uuid: 'uuid-from-editor', assetTagNumber: 'TAG-123' }));
assert.equal(cfg.asset.uuid, 'uuid-from-editor');
assert.equal(cfg.asset.tagCode, 'TAG-123');
assert.equal(cfg.asset.tagNumber, 'TAG-123');
});
test('buildDomainConfig prefers explicit assetUuid/assetTagCode when present', () => {
const cfg = callBuildDomainConfig(makeUiConfig({
uuid: 'legacy-uuid', assetUuid: 'explicit-uuid',
assetTagNumber: 'legacy-tag', assetTagCode: 'explicit-tag',
}));
assert.equal(cfg.asset.uuid, 'explicit-uuid');
assert.equal(cfg.asset.tagCode, 'explicit-tag');
});
test('buildDomainConfig builds explicit curveUnits and falls back for invalid flow unit', () => {
const cfg = callBuildDomainConfig(makeUiConfig({
unit: 'not-a-unit',
curvePressureUnit: 'mbar', curveFlowUnit: 'm3/h',
curvePowerUnit: 'kW', curveControlUnit: '%',
}));
assert.equal(cfg.general.unit, 'm3/h');
assert.equal(cfg.asset.unit, 'm3/h');
assert.equal(cfg.asset.curveUnits.pressure, 'mbar');
assert.equal(cfg.asset.curveUnits.flow, 'm3/h');
assert.equal(cfg.asset.curveUnits.power, 'kW');
assert.equal(cfg.asset.curveUnits.control, '%');
});
test('buildDomainConfig stashes state config including logging + movement + time', () => {
Machine._pendingExtras = null;
const inst = Object.create(NodeClass.prototype);
inst.buildDomainConfig(makeUiConfig({ enableLog: true, logLevel: 'warn', speed: 5, startup: 3 }));
const extras = Machine._pendingExtras;
assert.ok(extras, 'Machine._pendingExtras should be set by buildDomainConfig');
assert.equal(extras.stateConfig.general.logging.enabled, true);
assert.equal(extras.stateConfig.general.logging.logLevel, 'warn');
assert.equal(extras.stateConfig.movement.speed, 5);
assert.equal(extras.stateConfig.time.starting, 3);
Machine._pendingExtras = null;
});