const test = require('node:test');
const assert = require('node:assert/strict');
const Machine = require('../../src/specificClass');
const NodeClass = require('../../src/nodeClass');
const { makeMachineConfig, makeStateConfig, makeNodeStub } = require('../helpers/factories');
test('setpoint rejects negative inputs without throwing', async () => {
const machine = new Machine(makeMachineConfig(), makeStateConfig({ state: { current: 'operational' } }));
await assert.doesNotReject(async () => {
await machine.setpoint(-1);
});
});
test('setpoint is constrained to safe movement/curve bounds', async () => {
const machine = new Machine(makeMachineConfig(), makeStateConfig({ state: { current: 'operational' } }));
const requested = [];
machine.state.moveTo = async (target) => {
requested.push(target);
};
const stateMin = machine.state.movementManager.minPosition;
const stateMax = machine.state.movementManager.maxPosition;
const curveMin = machine.predictFlow.currentFxyXMin;
const curveMax = machine.predictFlow.currentFxyXMax;
const min = Math.max(stateMin, curveMin);
const max = Math.min(stateMax, curveMax);
await machine.setpoint(min - 100);
await machine.setpoint(max + 100);
assert.equal(requested.length, 2);
assert.equal(requested[0], min);
assert.equal(requested[1], max);
});
test('nodeClass _updateNodeStatus returns error status on internal failure', () => {
const inst = Object.create(NodeClass.prototype);
const node = makeNodeStub();
inst.node = node;
inst.source = {
currentMode: 'auto',
state: {
getCurrentState() {
throw new Error('boom');
},
},
};
const status = inst._updateNodeStatus();
assert.equal(status.text, 'Status Error');
assert.equal(node._errors.length, 1);
});
test('measurement handlers reject incompatible units', () => {
const machine = new Machine(makeMachineConfig(), makeStateConfig({ state: { current: 'operational' } }));
assert.equal(machine.isUnitValidForType('flow', 'm3/h'), true);
assert.equal(machine.isUnitValidForType('flow', 'mbar'), false);
machine.updateMeasuredFlow(100, 'downstream', {
timestamp: Date.now(),
unit: 'mbar',
childName: 'bad-ft',
});
const measuredFlow = machine.measurements
.type('flow')
.variant('measured')
.position('downstream')
.getCurrentValue();
assert.equal(measuredFlow, null);
});