Consumer half of the abort-token mechanism added in generalFunctions
state.js. executeSequence captures host.state.sequenceAbortToken at
entry, then re-checks before every state transition and after the
optional ramp-down. If MGC (or any external caller) bumps the token
mid-sequence, the loop bails out cleanly — no more barge-through where
a pre-empted shutdown advances through stopping → coolingdown after a
fresh demand has already engaged the pump.
Without this the MGC rendezvous planner can't reliably re-dispatch a
pump that's mid-shutdown: the new flowmovement claims the gate, but
the old shutdown's for-loop keeps running on microtasks and steps the
FSM into idle/off underneath it.
Also: wiki regen following the same visual-first 14-section template as
the other EVOLV nodes — Reference-{Architecture,Contracts,Examples,
Limitations}.md split with _Sidebar.md index.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
For all 11 nodes with auto-gen markers: wiki/Home.md sections 5 (topic
contract) and 9 (data model) regenerated via npm run wiki:all. New
Unit column shows '<measure> (default <unit>)' for declared topics,
'—' otherwise. Effect column now uses descriptor.description (P11.2
field) overriding the generic per-prefix fallback.
For rotatingMachine + reactor: Phase 10 test rewrites — 3 + 8 files
moved off private nodeClass internals (_attachInputHandler, _commands,
_pendingExtras, _registerChild, _tick, etc.) to the public
BaseNodeAdapter surface (node.handlers.input, node.source.*).
+6 / +7 net new tests.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>