From 5ea0b0bda67ab98ccbee9898d0026cf048435b27 Mon Sep 17 00:00:00 2001 From: znetsixe Date: Sun, 17 May 2026 19:44:48 +0200 Subject: [PATCH] feat(state): honor sequenceAbortToken so external aborts cleanly break sequences MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Consumer half of the abort-token mechanism added in generalFunctions state.js. executeSequence captures host.state.sequenceAbortToken at entry, then re-checks before every state transition and after the optional ramp-down. If MGC (or any external caller) bumps the token mid-sequence, the loop bails out cleanly — no more barge-through where a pre-empted shutdown advances through stopping → coolingdown after a fresh demand has already engaged the pump. Without this the MGC rendezvous planner can't reliably re-dispatch a pump that's mid-shutdown: the new flowmovement claims the gate, but the old shutdown's for-loop keeps running on microtasks and steps the FSM into idle/off underneath it. Also: wiki regen following the same visual-first 14-section template as the other EVOLV nodes — Reference-{Architecture,Contracts,Examples, Limitations}.md split with _Sidebar.md index. Co-Authored-By: Claude Opus 4.7 (1M context) --- src/state/sequenceController.js | 18 ++ wiki/Home.md | 408 ++++++++------------------------ wiki/Reference-Architecture.md | 340 ++++++++++++++++++++++++++ wiki/Reference-Contracts.md | 279 ++++++++++++++++++++++ wiki/Reference-Examples.md | 169 +++++++++++++ wiki/Reference-Limitations.md | 105 ++++++++ wiki/_Sidebar.md | 19 ++ 7 files changed, 1034 insertions(+), 304 deletions(-) create mode 100644 wiki/Reference-Architecture.md create mode 100644 wiki/Reference-Contracts.md create mode 100644 wiki/Reference-Examples.md create mode 100644 wiki/Reference-Limitations.md create mode 100644 wiki/_Sidebar.md diff --git a/src/state/sequenceController.js b/src/state/sequenceController.js index 5126612..0629afa 100644 --- a/src/state/sequenceController.js +++ b/src/state/sequenceController.js @@ -63,6 +63,15 @@ async function executeSequence(host, rawName) { host.logger.warn(`Sequence '${name}' not defined.`); return; } + // Snapshot the sequence-abort token at entry, BEFORE any awaits. If an + // external abort advances the counter while we're inside this call + // (setpoint ramp-down, waitForOperational, or the state transition + // loop), every check below sees the mismatch and breaks out so the + // new dispatch can claim the FSM. Capturing later would conflate the + // abort that fired during setpoint(0) with the initial entry state. + const startToken = host.state.sequenceAbortToken ?? 0; + const aborted = () => (host.state.sequenceAbortToken ?? 0) !== startToken; + const interruptible = new Set(['shutdown', 'emergencystop']); if (interruptible.has(name)) host.state.delayedMove = null; const current = host.state.getCurrentState(); @@ -74,9 +83,18 @@ async function executeSequence(host, rawName) { if (host.state.getCurrentState() === 'operational' && name === 'shutdown') { host.logger.info(`Machine will ramp down to position 0 before performing ${name} sequence`); await setpoint(host, 0); + if (aborted()) { + host.logger.warn(`Sequence '${name}' interrupted during ramp-down by external abort; not entering shutdown loop.`); + host.updatePosition(); + return; + } } host.logger.info(` --------- Executing sequence: ${name} -------------`); for (const s of sequence) { + if (aborted()) { + host.logger.warn(`Sequence '${name}' interrupted at step '${s}' by external abort; stopping further transitions.`); + break; + } try { await host.state.transitionToState(s); } catch (e) { host.logger.error(`Error during sequence '${name}': ${e}`); break; } } diff --git a/wiki/Home.md b/wiki/Home.md index f455af8..aeb7a82 100644 --- a/wiki/Home.md +++ b/wiki/Home.md @@ -1,20 +1,32 @@ # rotatingMachine -> **Reflects code as of `1a9f533` · regenerated `2026-05-11` via `npm run wiki:all`** -> If this banner is stale, the page may be out of date. Treat as informative, not authoritative. +![code-ref](https://img.shields.io/badge/code--ref-394a972-blue) ![s88](https://img.shields.io/badge/S88-Equipment_Module-86bbdd) ![status](https://img.shields.io/badge/status-trial--ready-brightgreen) -## 1. What this node is +A `rotatingMachine` models a single pump, compressor, or blower. It loads a supplier characteristic curve, takes upstream + downstream pressure measurements (real or simulated), predicts the resulting flow + power, drives a startup / shutdown state machine, and assesses prediction drift against measured flow / power. Used as a child of `machineGroupControl` when grouped, or directly under `pumpingStation` for a one-pump station. -**rotatingMachine** models a single pump, compressor, or blower. It loads a supplier characteristic curve, takes upstream + downstream pressure measurements (or simulated values), predicts the resulting flow + power, drives a startup/shutdown state machine, and assesses prediction drift against measured flow / power. Used as a child of `machineGroupControl` when grouped, or directly under a `pumpingStation`. +--- -## 2. Position in the platform +## At a glance + +| Thing | Value | +|:---|:---| +| What it represents | One rotating asset on a curve — pump, blower, compressor | +| S88 level | Equipment Module | +| Use it when | You have a curve-modelled asset whose flow / power varies with header differential and you want predictions + drift | +| Don't use it for | Passive non-return valves (`valve`), curveless assets (will silently emit zeros), groups (parent under `machineGroupControl`) | +| Children it accepts | `measurement` (pressure / flow / power / temperature) | +| Parents it talks to | `machineGroupControl`, `pumpingStation`, or any node that issues `flowmovement` / `execsequence` | + +--- + +## How it fits ```mermaid flowchart LR parent[machineGroupControl /
pumpingStation]:::unit -->|flowmovement
execsequence| rm[rotatingMachine
Equipment]:::equip - m_up[measurement
pressure upstream]:::ctrl -.data.-> rm - m_dn[measurement
pressure downstream]:::ctrl -.data.-> rm - sim[dashboard-sim
virtual pressure children]:::ctrl -.data.-> rm + m_up[measurement
pressure upstream]:::ctrl -.measured.-> rm + m_dn[measurement
pressure downstream]:::ctrl -.measured.-> rm + sim[dashboard-sim-upstream /
dashboard-sim-downstream
(auto-registered virtual children)]:::ctrl -.measured.-> rm rm -->|child.register| parent rm -.->|flow.predicted.*
power.predicted.atequipment| parent classDef unit fill:#50a8d9,color:#000 @@ -22,331 +34,119 @@ flowchart LR classDef ctrl fill:#a9daee,color:#000 ``` -S88 colours: Unit `#50a8d9`, Equipment `#86bbdd`, Control Module `#a9daee`. Source of truth: `.claude/rules/node-red-flow-layout.md`. +S88 colours are anchored in `.claude/rules/node-red-flow-layout.md`. -## 3. Capability matrix +--- -| Capability | Status | Notes | -|---|---|---| -| Curve-based flow prediction | ✅ | Built from `asset.model` via `curves/curveLoader`. | -| Curve-based power prediction | ✅ | Reverse curve composed inside `buildPredictors`. | -| FSM (startup / shutdown / movement) | ✅ | Shared `state/state.js` from generalFunctions. | -| Interruptible movements | ✅ | `abortMovement` from MGC overrides on new demand. | -| Drift assessment (flow + power) | ✅ | `DriftAssessor` with EWMA + alignment tolerance. | -| Virtual pressure children for sim | ✅ | `dashboard-sim-upstream / -downstream`. | -| Real-pressure child preference | ✅ | `pressureSelector` prefers real over virtual. | -| Group operating-point prediction | ✅ | `setGroupOperatingPoint` for MGC integration. | -| `cmd.estop` hard cut | ✅ | Forces `emergencystop` state. | -| `data.simulate-measurement` injection | ✅ | Pressure / flow / power / temperature. | -| Auto-recovery from prediction loss | ⚠️ | Reverts to null predictors silently — health falls to `invalid`. | -| Multi-parent registration | ⚠️ | Accepted but not exercised in production. | +## Try it — 3-minute demo -## 4. Code map +Import the basic example flow, deploy, and drive a single pump through the full state machine. -```mermaid -flowchart TB - subgraph nodeRED["nodeClass.js — adapter (BaseNodeAdapter)"] - nc["buildDomainConfig()
static DomainClass, commands"] - end - subgraph domain["specificClass.js — orchestrator (BaseDomain)"] - sc["Machine.configure()
_setupCurves / _setupState /
_setupDrift / _setupPressure /
_setupChildren"] - end - subgraph concerns["src/ concern modules"] - curves["curves/
loadModelCurve + normalize"] - prediction["prediction/
buildPredictors + math"] - drift["drift/
DriftAssessor + healthRefresh"] - pressure["pressure/
init + router + selector + virtual"] - state["state/
FSM bindings + sequenceController"] - measurement["measurement/
handlers + childRegistrar"] - flow["flow/
flowController (handleInput)"] - display["display/
workingCurves + CoG"] - io["io/
output + status"] - commands["commands/
topic registry + handlers"] - end - nc --> sc - sc --> curves - sc --> prediction - sc --> drift - sc --> pressure - sc --> state - sc --> measurement - sc --> flow - sc --> display - sc --> io - nc --> commands +```bash +curl -X POST -H 'Content-Type: application/json' \ + --data @nodes/rotatingMachine/examples/01\ -\ Basic\ Manual\ Control.json \ + http://localhost:1880/flow ``` -| Module | Owns | Read first if you're changing… | -|---|---|---| -| `curves/` | Supplier curve loader + normaliser + reverse | Curve fitting, unit mismatches, fallback. | -| `prediction/` | Per-machine + group predictors, math helpers | Predicted flow / power values. | -| `drift/` | DriftAssessor (EWMA, alignment), healthRefresh | Prediction quality, flags, confidence. | -| `pressure/` | init + router + selector + virtual children | Pressure plumbing, sim vs real preference. | -| `state/` | FSM bindings + setpoint / sequence orchestration | Startup / shutdown sequences. | -| `measurement/` | Measurement handlers + child registrar | Measured value plumbing per type. | -| `flow/` | `flowController.handle(source, action, parameter)` | Top-level input dispatch. | -| `display/` | `showWorkingCurves`, `showCoG` | `query.curves` / `query.cog` outputs. | -| `io/` | `getOutput`, `getStatusBadge` | Output shape, badge text. | -| `commands/` | Input-topic registry and handlers | New input topics, payload validation. | +What to click after deploy (the inject buttons map one-to-one to topics in [Reference — Contracts](Reference-Contracts#topic-contract)): -## 5. Topic contract +1. `data.simulate-measurement` (upstream + downstream) — injects ~0 mbar suction and ~1100 mbar discharge so the predictor has something to work with. +2. `set.mode = virtualControl` — lets the GUI source drive the pump (parent path is for grouped use). +3. `cmd.startup` — FSM runs `idle → starting → warmingup → operational`. `runtime` starts accumulating. +4. `set.setpoint = 60` (control %) — pump ramps from `0` to `60` at the configured `Reaction Speed`; state goes `operational → accelerating → operational`. +5. `set.flow-setpoint = {value: 80, unit: "m3/h"}` — same path, but the setpoint is a flow value; the node converts via `predictCtrl` to a control %. +6. `cmd.shutdown` — `operational → decelerating → stopping → coolingdown → idle`. -> **Auto-generated** from `src/commands/index.js`. Do NOT hand-edit between the markers. Re-run `npm run wiki:contract`. +> [!IMPORTANT] +> **GIF needed.** Demo recording of steps 1–6 with the live status panel. Save as `wiki/_partial-gifs/rotatingMachine/01-basic-demo.gif`, target ≤ 1 MB after `gifsicle -O3 --lossy=80`. - +--- -| Canonical topic | Aliases | Payload | Unit | Effect | -|---|---|---|---|---| -| `set.mode` | `setMode` | `string` | — | Switch the machine between auto / manual control modes. | -| `cmd.startup` | _(none)_ | `any` | — | Initiate the machine startup sequence. | -| `cmd.shutdown` | _(none)_ | `any` | — | Initiate the machine shutdown sequence. | -| `cmd.estop` | `emergencystop` | `any` | — | Trigger an emergency stop. | -| `execSequence` | _(none)_ | `object` | — | Legacy umbrella that demuxes payload.action to startup / shutdown. | -| `set.setpoint` | `execMovement` | `object` | — | Move the machine to a control-% setpoint via execMovement. | -| `set.flow-setpoint` | `flowMovement` | `object` | `volumeFlowRate` (default `m3/h`) | Move the machine to a flow setpoint via flowMovement. | -| `data.simulate-measurement` | `simulateMeasurement` | `object` | — | Inject a simulated sensor reading (pressure/flow/temperature/power). | -| `query.curves` | `showWorkingCurves` | `any` | — | Return the working curves for the machine on the reply port. | -| `query.cog` | `CoG` | `any` | — | Return the centre-of-gravity (CoG) point on the reply port. | -| `child.register` | `registerChild` | `string` | — | Register a child measurement with this machine. | +## The seven things you'll send - +| Topic | Aliases | Payload | What it does | +|:---|:---|:---|:---| +| `set.mode` | `setMode` | `"auto"` \| `"virtualControl"` \| `"fysicalControl"` | Switch between parent-controlled, GUI-controlled, and physical-source-only. Each mode has its own allow-list for actions and sources. | +| `cmd.startup` | — | any | Run the configured startup sequence (default `[starting, warmingup, operational]`). | +| `cmd.shutdown` | — | any | Run the configured shutdown sequence (default `[stopping, coolingdown, idle]`). `operational` triggers a ramp-to-zero first. | +| `cmd.estop` | `emergencystop` | any | Hard cut: runs the `emergencystop` sequence (default `[emergencystop, off]`). Reachable from every state. | +| `set.setpoint` | `execMovement` | `{setpoint: number}` (control %) | Move to a control-% setpoint. | +| `set.flow-setpoint` | `flowMovement` | `{setpoint: number}` (flow, unit per `units`) | Move to a flow setpoint. Converted to canonical m³/s, then to control % via `predictCtrl`. | +| `data.simulate-measurement` | `simulateMeasurement` | `{asset: {type, unit}, value, position, childId?}` | Inject a virtual sensor reading (pressure / flow / power / temperature). | -## 6. Child registration +Plus two query topics for dashboards: -`measurement` children register through `childRegistrationUtils`; the machine subscribes to the matching `.measured.` event. +| Topic | Aliases | Returns on the reply port | +|:---|:---|:---| +| `query.curves` | `showWorkingCurves` | The working curves (flow / power / efficiency) at the current operating point. | +| `query.cog` | `CoG` | The centre-of-gravity (CoG) of the η curve. | -```mermaid -flowchart LR - subgraph kids["accepted children (softwareType)"] - m_pu["measurement
type=pressure
position=upstream"]:::ctrl - m_pd["measurement
type=pressure
position=downstream"]:::ctrl - m_f["measurement
type=flow"]:::ctrl - m_pw["measurement
type=power"]:::ctrl - m_t["measurement
type=temperature"]:::ctrl - end - m_pu -->|pressure.measured.upstream| router[pressureRouter.route] - m_pd -->|pressure.measured.downstream| router - m_f -->|flow.measured.| mh[measurementHandlers] - m_pw -->|power.measured.atequipment| mh - m_t -->|temperature.measured.| mh - router --> upd[updatePosition + drift refresh] - mh --> upd - classDef ctrl fill:#a9daee,color:#000 -``` +--- -| softwareType | filter | wired to | side-effect | -|---|---|---|---| -| `measurement` | `type=pressure, position=upstream` | `pressureRouter.route('upstream', ...)` | Sets upstream pressure; refresh prediction + drift. | -| `measurement` | `type=pressure, position=downstream` | `pressureRouter.route('downstream', ...)` | Sets downstream pressure; refresh prediction + drift. | -| `measurement` | `type=flow, position=*` | `measurementHandlers.updateMeasuredFlow` | Stored; drift assessed against predicted. | -| `measurement` | `type=power, position=atEquipment` | `measurementHandlers.updateMeasuredPower` | Stored; drift assessed against predicted. | -| `measurement` | `type=temperature, position=*` | `measurementHandlers.updateMeasuredTemperature` | Stored; used by power correction if relevant. | +## What you'll see come out -Two **virtual children** are auto-registered at startup: `dashboard-sim-upstream` and `dashboard-sim-downstream`. `data.simulate-measurement` payloads land on these. Real pressure children, when registered, are preferred over the virtuals by `pressureSelector`. +Sample Port 0 message (delta-compressed, while operational at ~60 % control): -## 7. Lifecycle — what one event does - -```mermaid -sequenceDiagram - participant parent as MGC / pumpingStation - participant rm as rotatingMachine - participant fsm as state FSM - participant pred as predictors - participant out as Port-0 output - - parent->>rm: flowmovement (Q) - rm->>rm: flowController.handle('parent', 'flowmovement', Q) - rm->>fsm: setpoint(Q) → maybe transitionToState('accelerating') - Note over fsm: state.emitter 'positionChange' per tick - fsm-->>rm: positionChange → updatePosition() - rm->>pred: calcFlowPower(x) → cFlow, cPower - rm->>rm: calcEfficiency / cog / distance-BEP - rm->>rm: drift refresh on every measured tick - rm->>out: msg{topic, payload} (delta-compressed) - parent->>rm: execsequence ('startup' | 'shutdown') - rm->>fsm: transitionToState('starting' | 'stopping') - fsm-->>rm: stateChange → _updateState() -``` - -## 8. Data model — `getOutput()` - -Composed in `io/output.js → buildOutput(this)`, then delta-compressed. - - - -| Key | Type | Unit | Sample | -|---|---|---|---| -| `NCog` | number | — | `0` | -| `NCogPercent` | number | — | `0` | -| `atmPressure.measured.atequipment.wikigen-rotatingmachine-id` | number | — | `101325` | -| `cog` | number | — | `0` | -| `ctrl` | number | — | `0` | -| `effDistFromPeak` | number | — | `0` | -| `effRelDistFromPeak` | number | — | `0` | -| `flow.predicted.max.wikigen-rotatingmachine-id` | number | m3/s | `0` | -| `flow.predicted.min.wikigen-rotatingmachine-id` | number | m3/s | `0` | -| `maintenanceTime` | number | — | `0` | -| `mode` | string | — | `"auto"` | -| `moveTimeleft` | number | — | `0` | -| `predictionConfidence` | number | — | `0` | -| `predictionFlags` | array | — | `[…]` | -| `predictionPressureSource` | null | — | `null` | -| `predictionQuality` | string | — | `"invalid"` | -| `pressureDriftFlags` | array | — | `[…]` | -| `pressureDriftLevel` | number | — | `0` | -| `pressureDriftSource` | null | — | `null` | -| `runtime` | number | — | `0` | -| `state` | string | — | `"idle"` | -| `temperature.measured.atequipment.wikigen-rotatingmachine-id` | number | K | `15` | - - - -**Concrete sample** (live, from a known-good test run — pump warming up with simulated upstream/downstream pressure): - -~~~json +```json { - "state": "warmingup", - "ctrl": 42.5, - "mode": "auto", - "runtime": 0.0014, - "flow.predicted.downstream.default": 12.4, - "flow.predicted.atequipment.default": 12.4, - "flow.predicted.max.dashboard-sim-upstream": 22.1, - "flow.predicted.min.dashboard-sim-upstream": 0, - "power.predicted.atequipment.default": 18.2, - "pressure.measured.upstream.dashboard-sim-upstream": 101325, - "pressure.measured.downstream.dashboard-sim-downstream": 145000, - "temperature.measured.atequipment.dashboard-sim-upstream": 15, - "atmPressure.measured.atequipment.dashboard-sim-upstream": 101325, - "predictionQuality": "warming", - "predictionConfidence": 0.35, - "predictionPressureSource": "dashboard-sim", - "predictionFlags": ["pressure_init_warming"], - "pressureDriftLevel": 0, - "pressureDriftSource": null, - "pressureDriftFlags": ["nominal"], - "cog": 0.62, "NCog": 0.71, "NCogPercent": 62, - "effDistFromPeak": 0.04, "effRelDistFromPeak": 0.12, - "moveTimeleft": 0, "maintenanceTime": 0 + "topic": "rotatingMachine#pump_a", + "payload": { + "state": "operational", + "ctrl": 60.0, + "mode": "auto", + "runtime": 0.024, + "flow.predicted.downstream.default": 12.4, + "flow.predicted.atequipment.default": 12.4, + "power.predicted.atequipment.default": 18.2, + "pressure.measured.upstream.dashboard-sim-upstream": 0, + "pressure.measured.downstream.dashboard-sim-downstream": 1100, + "predictionQuality": "good", + "predictionConfidence": 0.92, + "predictionPressureSource": "dashboard-sim", + "predictionFlags": [], + "cog": 0.62, "NCog": 0.71, "NCogPercent": 62, + "effDistFromPeak": 0.04, "effRelDistFromPeak": 0.12 + } } -~~~ - -Position labels are normalised to lowercase in MeasurementContainer keys (`atequipment`, `downstream`, `upstream`, `max`, `min`). The trailing `` segment is the registering child's id (or `default` for own predictions / virtuals tagged via `dashboard-sim-*`). - -## 9. Configuration — editor form ↔ config keys - -```mermaid -flowchart TB - subgraph editor["Node-RED editor form"] - f1[Asset — supplier / category / model / unit] - f2[Position vs parent] - f3[State times: startup / warmup / shutdown / cooldown] - f4[Movement mode + reaction speed] - f5[Process output format] - f6[Database output format] - f7[Logger — level / enabled] - end - subgraph cfg["Domain config slice"] - c1[asset.model / asset.unit / asset.supplier / asset.category] - c2[functionality.positionVsParent] - c3[time.starting / warmingup / stopping / coolingdown] - c4[movement.mode / movement.speed] - c5[output.process] - c6[output.dbase] - c7[general.logging] - end - f1 --> c1 - f2 --> c2 - f3 --> c3 - f4 --> c4 - f5 --> c5 - f6 --> c6 - f7 --> c7 ``` -| Form field | Config key | Default | Range | Where used | -|---|---|---|---|---| -| Asset model | `asset.model` | `Unknown` | string (must resolve in curve loader) | `_setupCurves` | -| Asset flow unit | `asset.unit` | `m3/h` | unit string | unit policy `output.flow` | -| Position vs parent | `functionality.positionVsParent` | `atEquipment` | enum (`upstream`, `atEquipment`, `downstream`) | child-register payload + event suffix | -| State time — starting | `time.starting` | `10` (s) | ≥ 0 | FSM timing | -| State time — warmingup | `time.warmingup` | `5` (s) | ≥ 0 | FSM timing | -| State time — stopping | `time.stopping` | `5` (s) | ≥ 0 | FSM timing | -| State time — coolingdown | `time.coolingdown` | `10` (s) | ≥ 0 | FSM timing | -| Movement mode | `movement.mode` | `staticspeed` | enum (`staticspeed`, `dynspeed`) | position trajectory | -| Reaction speed | `movement.speed` | `1` | ≤ `maxSpeed` | trajectory ramp rate (%/s) | -| Process output format | `output.process` | `process` | enum (`process`, `json`, `csv`) | Port 0 formatter | -| Database output format | `output.dbase` | `influxdb` | enum (`influxdb`, `json`, `csv`) | Port 1 formatter | +Key shape: **`...`** — the inverse of MGC's key shape, because rotatingMachine emits per-measurement snapshots. The trailing `` is the registering child's id (`dashboard-sim-upstream`, `dashboard-sim-downstream`, or `default` for own predictions). Position labels are normalised to lowercase in keys. -## 10. State chart +| Field | Meaning | +|:---|:---| +| `state` | Current FSM state. See [Architecture — FSM](Reference-Architecture#fsm). | +| `ctrl` | Control-axis position (`0..100`). | +| `mode` | One of `auto` / `virtualControl` / `fysicalControl`. | +| `runtime` | Accumulated hours in active states (operational and movement variants). | +| `flow.predicted.{downstream,atequipment}.default` | Predicted flow at the current operating point (canonical m³/s; renders to `m3/h`). | +| `power.predicted.atequipment.default` | Predicted shaft power (canonical W; renders to `kW`). | +| `predictionQuality` | `good` / `warming` / `degraded` / `invalid` — derived by `predictionHealth` from drift + pressure availability. | +| `predictionPressureSource` | `dashboard-sim` (virtual children active) or a real-child id (real children preferred). | +| `predictionFlags` | Reason codes when health < `good` (e.g. `pressure_init_warming`, `flow_high_drift`). | +| `cog` / `NCog` / `NCogPercent` | Centre-of-gravity metric on the η curve. `NCog` is normalised 0..1. | +| `effDistFromPeak` / `effRelDistFromPeak` | Distance from the η peak (absolute and 0..1 relative). | -The FSM is the canonical state set declared in `generalFunctions/src/state/stateConfig.json`. `emergencystop` is reachable from *every* state. Allowed transitions per `stateConfig.allowedTransitions`. +--- -```mermaid -stateDiagram-v2 - [*] --> idle - idle --> starting: execsequence(startup) - idle --> off: off - idle --> maintenance: maintenance - starting --> warmingup: timer - warmingup --> operational: timer - operational --> accelerating: flowmovement / setpoint up - operational --> decelerating: flowmovement / setpoint down - accelerating --> operational: target reached - decelerating --> operational: target reached - operational --> stopping: execsequence(shutdown) - stopping --> coolingdown: timer - stopping --> idle: timer - coolingdown --> idle: timer - coolingdown --> off: off - off --> idle: execsequence(startup) - off --> maintenance: maintenance - maintenance --> idle: maintenance done - maintenance --> off: off +## The new bit — sequence-abort token - note right of operational - any state -> emergencystop - via cmd.estop - end note -``` +When a parent MGC sends a new demand, it calls `abortMovement` to interrupt any in-flight `accelerating` / `decelerating` movement. Before 2026-05-15 that abort only stopped the moveTo — an in-flight `executeSequence('shutdown')` for-loop would keep transitioning the FSM through `stopping → coolingdown → idle`, fighting the new dispatch's residue-handler. -`accelerating` / `decelerating` are abortable on new demand via `abortMovement(reason)`; the controller does **not** auto-transition back to `operational` after an abort (see `state.js` comment "Abort path"). `warmingup` and `coolingdown` are **protected** — abort signals are dropped for safety. `activeStates = { operational, starting, warmingup, accelerating, decelerating }` is the set MGC treats as "machine alive". +The pump now carries a monotonic `sequenceAbortToken` on its state object. External aborts (the kind MGC fires) advance it; sequence-internal aborts (e.g. shutdown's own pre-empt of its ramp-down step) do not. `executeSequence` captures the token at entry and bails out before its next transition if the counter has advanced. -## 11. Examples +Net effect: a mid-decel re-engage takes the pump cleanly back to operational, without the orphaned shutdown completing in the background. `warmingup` and `coolingdown` remain protected at the stateManager layer — safety guarantees are unchanged. -| Tier | File | What it shows | Status | -|---|---|---|---| -| Basic | `examples/01 - Basic Manual Control.json` | Inject + dashboard, simulated pressure, manual startup/shutdown | ✅ validated | -| Integration | `examples/02 - Integration with Machine Group.json` | rotatingMachine wired under MGC | ⏳ pending validation | -| Dashboard | `examples/03 - Dashboard Visualization.json` | FlowFuse charts: flow / power / pressure trends | ✅ in repo | -| Legacy | `examples/basic.flow.json` / `integration.flow.json` / `edge.flow.json` | Pre-refactor flows | ⚠️ kept until new Tier 2 is validated | +See [Architecture — FSM](Reference-Architecture#fsm) for the full mechanism. -Screenshots will land under `wiki/_partial-screenshots/rotatingMachine/` once captured from the live demo. +--- -## 12. Debug recipes +## Need more? -| Symptom | First thing to check | Where to look | -|---|---|---| -| `state` stuck on `idle`, no startup | Source not in `mode.allowedSources[currentMode]`. Check `flowController` warn log. | `_setupState` + `isValidSourceForMode`. | -| `flow.predicted.*` is 0 or `NaN` | Pressure not initialised — `predictionHealth.flags` will say `pressure_init_warming`. Inject pressure via `data.simulate-measurement` or wire real measurement children. | `getMeasuredPressure` + `pressureSelector`. | -| `predictionHealth.quality='invalid'` | Curve normalisation failed at startup — null predictors installed. Check container log for `Curve normalization failed for model …`. | `_setupCurves`. | -| Drift `level=3` after startup | Less than 10 paired samples (`minSamplesForLongTerm`) — wait a few ticks before judging. | `driftProfiles.minSamplesForLongTerm`. | -| `cmd.estop` doesn't recover | After `emergencystop`, only `idle` / `off` / `maintenance` are allowed. Send `cmd.shutdown` then `cmd.startup`, or reset via maintenance. | `stateConfig.allowedTransitions.emergencystop`. | -| Position bounces around target | Movement mode `dynspeed` ease-in/out may overshoot at high speed; try `staticspeed`. | `movement.mode`. | +| Page | What you'll find | +|:---|:---| +| [Reference — Contracts](Reference-Contracts) | Full topic contract, config schema, child registration filters | +| [Reference — Architecture](Reference-Architecture) | Code map, FSM, prediction pipeline, drift, lifecycle | +| [Reference — Examples](Reference-Examples) | Shipped example flows + debug recipes | +| [Reference — Limitations](Reference-Limitations) | When not to use, known limitations, open questions | -> Never ship `enableLog: 'debug'` in a demo — fills the container log within seconds and obscures real errors. - -## 13. When you would NOT use this node - -- Use rotatingMachine for a **single** pump / compressor / blower. For groups of 2+ with load sharing, wire `machineGroupControl` as the parent. -- Don't use rotatingMachine to model a **passive non-return valve** — use `valve` (no curve, no FSM-driven motor). -- Don't use rotatingMachine without a **curve model** — flow / power predictions degrade to zero and drift is meaningless. - -## 14. Known limitations / current issues - -| # | Issue | Tracked in | -|---|---|---| -| 1 | Drift confidence drops to 0 when pressure source is missing > 30 s — health flips to `invalid` silently. | `pressure/pressureInitialization.js`. | -| 2 | Multi-parent registration accepted by `childRegistrationUtils` but ordering of teardown is not test-covered. | Open question — `OPEN_QUESTIONS.md`. | -| 3 | `data.simulate-measurement` does not unset previous values on missing keys — stale sim data can persist after toggling off. | `measurementHandlers.updateSimulatedMeasurement`. | -| 4 | `execSequence` legacy umbrella topic kept alive in registry; planned removal in Phase 7. | `commands/index.js` `_legacy: true`. | +[EVOLV master wiki](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Home) · [Topology Patterns](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topology-Patterns) · [Topic Conventions](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions) diff --git a/wiki/Reference-Architecture.md b/wiki/Reference-Architecture.md new file mode 100644 index 0000000..7e761c8 --- /dev/null +++ b/wiki/Reference-Architecture.md @@ -0,0 +1,340 @@ +# Reference — Architecture + +![code-ref](https://img.shields.io/badge/code--ref-394a972-blue) + +> [!NOTE] +> Code structure for `rotatingMachine`: the three-tier sandwich, the `src/` layout, the FSM (with the new sequence-abort token), the prediction + drift pipeline, the lifecycle, and the output-port pipeline. For an intuitive overview, return to [Home](Home). + +--- + +## Three-tier code layout + +``` +nodes/rotatingMachine/ +| ++-- rotatingMachine.js entry: RED.nodes.registerType('rotatingMachine', NodeClass) +| ++-- src/ +| nodeClass.js extends BaseNodeAdapter (Node-RED bridge) +| specificClass.js extends BaseDomain (orchestration only) +| | +| +-- commands/ +| | index.js topic descriptors +| | handlers.js pure handler functions +| | +| +-- curves/ +| | curveLoader.js load supplier curve by model id +| | curveNormalizer.js unit + shape normalisation +| | reverseCurve.js invert flow → ctrl for predictCtrl +| | +| +-- prediction/ +| | predictors.js buildPredictors(curve) → predictFlow / Power / Ctrl +| | groupPredictors.js buildGroupPredictors() for MGC integration +| | predictionMath.js calcFlow / calcPower / calcCtrl / inputFlowCalcPower +| | efficiencyMath.js calcCog / calcEfficiency / calcDistanceBEP +| | operatingPoint.js legacy hook kept for migrations +| | +| +-- drift/ +| | driftAssessor.js per-metric drift pipeline (EWMA + alignment) +| | healthRefresh.js updates predictionHealth + pressureDrift +| | predictionHealth.js derives quality / confidence / flags +| | +| +-- pressure/ +| | pressureInitialization.js pressure-source readiness tracker +| | pressureRouter.js routes upstream / downstream measurements +| | pressureSelector.js pushes fDimension onto predictors +| | virtualChildren.js auto-registered dashboard-sim children +| | +| +-- state/ +| | stateBindings.js wires state.emitter to host callbacks +| | sequenceController.js setpoint / executeSequence / waitForOperational +| | +| +-- measurement/ +| | measurementHandlers.js per-type handlers (flow / power / temperature) +| | childRegistrar.js filter-aware listener attach / detach +| | +| +-- flow/ +| | flowController.js action dispatch (handleInput) +| | +| +-- display/ +| | workingCurves.js query.curves / query.cog reply shape +| | +| +-- io/ +| output.js getOutput() shape + status badge +``` + +### Tier responsibilities + +| Tier | File | What it owns | Touches `RED.*` | +|:---|:---|:---|:---:| +| entry | `rotatingMachine.js` | Type registration | Yes | +| nodeClass | `src/nodeClass.js` | Input routing, output ports, status-badge polling (`statusInterval=1000`). Stashes `stateConfig` and `errorMetricsConfig` on the class for the constructor. No tick loop — event-driven. | Yes | +| specificClass | `src/specificClass.js` | Wire concern modules in `configure()`; expose the same public surface MGC + pumpingStation already call (`handleInput`, `abortMovement`, `setGroupOperatingPoint`, `registerChild`, …); delegate everything else. | No | + +`specificClass` is stitching. All real work lives in the concern modules: pure math in `prediction/`, `drift/`; live-state-touching in `pressure/`, `state/`, `measurement/`, `flow/`. + +--- + +## FSM + +The state machine is declared in `generalFunctions/src/state/stateConfig.json`. Allowed transitions (relevant subset): + +```mermaid +stateDiagram-v2 + [*] --> idle + idle --> starting: startup + idle --> off + idle --> maintenance + starting --> warmingup: timer (time.starting) + warmingup --> operational: timer (time.warmingup) [protected] + operational --> accelerating: setpoint up + operational --> decelerating: setpoint down + operational --> stopping: shutdown + accelerating --> operational: target reached + decelerating --> operational: target reached + stopping --> coolingdown: timer (time.stopping) + coolingdown --> idle: timer (time.coolingdown) [protected] + coolingdown --> off + off --> idle: boot (first step) + off --> maintenance + maintenance --> off: exitmaintenance (step 1) + maintenance --> idle + + note right of operational + any state -> emergencystop via cmd.estop + from emergencystop: idle / off / maintenance + end note +``` + +Allowed transitions are declared in `generalFunctions/src/state/stateConfig.json` `allowedTransitions`. The diagram omits the `emergencystop` arrows for readability — every state has one. Self-edges (`starting → starting`, `maintenance → maintenance`) exist in the config for re-entrancy but aren't load-bearing. + +### Protected states + +`warmingup` and `coolingdown` are **protected** in `state.js` `transitionToState`. When the FROM-state is one of these, the abort signal passed to `stateManager.transitionTo` is nulled out: + +```js +const protectedStates = ['warmingup', 'coolingdown']; +const isProtectedTransition = protectedStates.includes(fromState); +if (isProtectedTransition) { + signal = null; + this.logger.warn(`Transition from ${fromState} to ${targetState} is protected and cannot be aborted.`); +} +``` + +So `abortCurrentMovement` cannot interrupt a warmup or cooldown. This is a deliberate safety guarantee — aborting a motor warmup risks burn-up. + +### Routine vs sequence-internal aborts + +`state.abortCurrentMovement(reason, options)` accepts: + +| Option | Default | Used by | Effect | +|:---|:---|:---|:---| +| `returnToOperational: false` | yes (default) | MGC's `abortActiveMovements` — new-demand aborts | Aborts the moveTo. Does NOT auto-transition to operational (avoids a bounce loop on per-tick aborts). **Advances `sequenceAbortToken`** so any in-flight `executeSequence` bails out. | +| `returnToOperational: true` | — | `executeSequence` itself when a fresher shutdown / e-stop pre-empts its own setpoint-to-zero step | Aborts the moveTo and auto-transitions back to operational so the sequence can proceed. Does NOT advance `sequenceAbortToken`. | + +### Sequence-abort token — what it does + +`state.sequenceAbortToken` is a monotonic counter, advanced on every external (non-internal) abort. `sequenceController.executeSequence` captures the value at entry: + +```js +const startToken = host.state.sequenceAbortToken ?? 0; +const aborted = () => (host.state.sequenceAbortToken ?? 0) !== startToken; +``` + +and checks before: + +1. Entering the for-loop (after the optional `setpoint(host, 0)` ramp-down step). +2. Every iteration of the state-transition for-loop. + +A mismatch breaks the loop early with `Sequence '' interrupted ... by external abort`. The pump's `updatePosition` runs anyway so output state stays consistent. + +Why this matters: without the token, a shutdown's for-loop continues to run after `abortMovement` rejects its `setpoint(host, 0)`. The pump can transition `operational → stopping → coolingdown → idle` even when a new dispatch has already taken the FSM back to operational via the residue handler. The token snapshot ensures only **one** of those two paths wins per dispatch. + +### Residue-state handling in `moveTo` + +`state.moveTo` recognises `accelerating` and `decelerating` as **post-abort residue states**. If a setpoint arrives in either, it transitions back to `operational` first, then proceeds with the new move: + +```js +const movementResidueStates = ['accelerating', 'decelerating']; +if (movementResidueStates.includes(this.stateManager.getCurrentState())) { + await this.transitionToState("operational"); + // Fall through — state is now operational, proceed with new move. +} +``` + +This is what makes mid-flight retargets work without parking the new setpoint in `delayedMove`. + +### `delayedMove` — deferred setpoint + +When a setpoint arrives while the FSM is in a genuinely non-operational, non-residue state (`starting`, `warmingup`, `stopping`, `coolingdown`, `idle`, `off`, `emergencystop`, `maintenance`) AND mode is `auto`, the value is stashed in `state.delayedMove`. The next transition INTO `operational` picks it up and fires `moveTo(delayedMove)`. So a flow setpoint sent during startup is queued, not lost. + +### State-entry timestamp + remaining transition + +`stateManager.stateEnteredAt` is wall-clock-stamped on every state assignment (constructor + both transition branches). `stateManager.getRemainingTransitionS()` returns `max(0, transitionTimes[currentState] − elapsed)`. The MGC movement planner calls this through `machineProfile.buildProfile` to compute exact rendezvous time for pumps currently in `warmingup` / `starting`. + +--- + +## Prediction + drift pipeline + +```mermaid +flowchart TB + sim[data.simulate-measurement]:::input --> pi[pressureInitialization] + real[measurement child
pressure.measured.up/down]:::input --> pi + pi --> ps[pressureSelector
prefers real over virtual] + ps --> fd[fDimension push:
predictFlow / predictPower / predictCtrl] + fd --> upd[updatePosition()] + upd --> calc[calcFlowPower(ctrl)] + calc --> meas[MeasurementContainer
flow.predicted.*
power.predicted.atequipment] + measFlow[flow.measured.*]:::input --> drift[DriftAssessor
EWMA + alignment] + measPower[power.measured.atequipment]:::input --> drift + meas --> drift + drift --> health[predictionHealth.refresh
quality / confidence / flags] + health --> out[Port 0] + upd --> out + classDef input fill:#a9daee,color:#000 +``` + +### Curve loading + +At `configure()` startup: + +1. `assetResolver.resolveAssetMetadata('rotatingmachine', model)` resolves supplier / type / allowed units from `generalFunctions/datasets/assetData/`. +2. `asset.unit` is validated (must be a flow unit) and soft-warned if not in the registry's recommended list. +3. `loadModelCurve(model)` reads the raw supplier curve. +4. `normalizeMachineCurve(rawCurve, unitPolicy, logger)` unit-converts and shape-normalises. +5. `buildPredictors(curve)` returns `{predictFlow, predictPower, predictCtrl}` where `predictCtrl` is the reverse curve (flow → control %). + +Any failure installs **null predictors** (the asset still loads but emits zeros). The status badge falls through to a `predictionQuality: 'invalid'` state on Port 0. + +### Drift + +`DriftAssessor` wraps `generalFunctions/nrmse` into per-metric drift profiles. Defaults (`flow` and `power`): + +| Field | Value | Notes | +|:---|:---|:---| +| `windowSize` | `30` | Sample count for long-term NRMSE | +| `minSamplesForLongTerm` | `10` | Below this, long-term level stays at 3 (=invalid) | +| `ewmaAlpha` | `0.15` | Immediate-level smoothing | +| `alignmentToleranceMs` | `2500` | Predicted ↔ measured timestamps must align within this | +| `strictValidation` | `true` | Reject samples on alignment failure | + +Drift feeds `predictionHealth.refresh` — immediate-level and long-term-level reduce `predictionConfidence` and append `flow_*_drift` / `power_*_drift` flags. Pressure drift is computed separately (real vs virtual divergence). + +### Virtual pressure children + +Two `measurement`-typed children are auto-registered at startup: + +| ID | Position | +|:---|:---| +| `dashboard-sim-upstream` | `upstream` | +| `dashboard-sim-downstream` | `downstream` | + +`data.simulate-measurement` payloads land on these. `pressureSelector` prefers any **real** pressure child over the virtuals once one registers; the virtuals stay live so the dashboard can keep injecting test values. + +--- + +## Lifecycle — what one event does + +```mermaid +sequenceDiagram + autonumber + participant parent as MGC / pumpingStation / GUI + participant rm as rotatingMachine + participant fc as flowController + participant fsm as state (FSM) + participant pred as predictors + participant out as Port 0 / 1 + + parent->>rm: flowmovement (Q, unit) + rm->>fc: flowController.handle('parent', 'flowmovement', Q) + fc->>fc: mode/source allow-list check + fc->>fc: convert Q (output unit → canonical m³/s) + fc->>fc: pos = host.calcCtrl(Q) + fc->>fsm: setpoint(pos) → state.moveTo(pos) + Note over fsm: residue handler may re-enter operational first + fsm-->>rm: positionChange events per move tick + rm->>pred: calcFlowPower(pos) → cFlow, cPower + rm->>rm: calcEfficiency / cog / distance-BEP + rm->>out: notifyOutputChanged (Port 0/1 delta) + parent->>rm: execsequence ('startup' | 'shutdown') + rm->>fsm: executeSequence → state transitions + fsm-->>rm: stateChange events → _updateState +``` + +### Mode + source allow-lists + +Each input is gated twice in `flowController.handle`: + +1. `host.isValidActionForMode(action, currentMode)` — matrix lives in `config.mode.allowedActions`. +2. `host.isValidSourceForMode(source, currentMode)` — matrix in `config.mode.allowedSources`. + +Defaults (per `generalFunctions/src/configs/rotatingMachine.json`): + +| Mode | Allowed actions | Allowed sources | +|:---|:---|:---| +| `auto` | `statuscheck, execmovement, execsequence, flowmovement, emergencystop, entermaintenance` | `parent, GUI, fysical` | +| `virtualControl` | `statuscheck, execmovement, flowmovement, execsequence, emergencystop, exitmaintenance` | `GUI, fysical` | +| `fysicalControl` | `statuscheck, emergencystop, entermaintenance, exitmaintenance` | `fysical` | + +A rejected action logs at warn (` is not allowed in mode ` or ` is not allowed in mode `) and short-circuits. + +--- + +## Output ports + +| Port | Carries | Sample shape | +|:---|:---|:---| +| 0 (process) | Delta-compressed state snapshot — FSM state, predictions, drift, prediction health | `{topic, payload: {state, ctrl, flow.predicted.*, power.predicted.*, predictionQuality, ...}}` | +| 1 (telemetry) | InfluxDB line-protocol payload (same fields as Port 0) | `rotatingMachine,id=pump_a state="operational",ctrl=60,flow_predicted_downstream_default=12.4,...` | +| 2 (register / control) | `child.register` upward at init | `{topic: 'child.register', payload: {ref, softwareType, config}}` | + +Port-0 key shape is **`...`**. The trailing `` lets dashboards distinguish the same measurement type / position registered from different sources (real sensor vs `dashboard-sim`). + +See [EVOLV — Telemetry](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Telemetry) for the full InfluxDB layout. + +--- + +## Event sources + +| Source | Where it fires | What it triggers | +|:---|:---|:---| +| `state.emitter` `'positionChange'` | `movementManager` setInterval during a move | `updatePosition()` — recompute predictions + Port 0 | +| `state.emitter` `'stateChange'` | `stateManager.transitionTo` resolve | `_updateState()` — zero predictions if non-operational, refresh health, Port 0 | +| `state.emitter` `'movementComplete'` | `state.moveTo` after a successful move | (subscribed but currently unused by orchestrator) | +| `state.emitter` `'movementAborted'` | `state.moveTo` catch on aborted move | (subscribed but currently unused) | +| Child measurement emitter | `child.measurements.emitter` per type / position | `pressureRouter.route` or `measurementHandlers.dispatch` | +| Inbound `msg.topic` | Node-RED input wire | `commandRegistry` dispatch | +| `setInterval(statusInterval = 1000)` | `BaseNodeAdapter` | Status badge re-render | + +No per-second tick on the domain itself. The movementManager's inner setInterval (50 ms by default) only runs while a position move is in flight. + +--- + +## Where to start reading + +| If you're changing... | Read first | +|:---|:---| +| Curve loading, normalisation, fallback | `src/curves/{curveLoader, curveNormalizer, reverseCurve}.js` | +| Per-machine + group predictors | `src/prediction/predictors.js`, `groupPredictors.js`, `predictionMath.js` | +| Drift detection (EWMA, alignment) | `src/drift/{driftAssessor, healthRefresh, predictionHealth}.js` | +| Pressure plumbing, virtual vs real preference | `src/pressure/{pressureInitialization, pressureRouter, pressureSelector, virtualChildren}.js` | +| FSM bindings, setpoint, sequence orchestration | `src/state/{stateBindings, sequenceController}.js` + `generalFunctions/src/state/{state, stateManager, movementManager}.js` | +| Sequence-abort token (the cooperating change for MGC's planner) | `generalFunctions/src/state/state.js` `abortCurrentMovement` + `src/state/sequenceController.js` `executeSequence` | +| Per-type measurement handlers | `src/measurement/{measurementHandlers, childRegistrar}.js` | +| Top-level action dispatch | `src/flow/flowController.js` | +| `query.curves` / `query.cog` outputs | `src/display/workingCurves.js` | +| Output shape, status badge | `src/io/output.js` | +| Topic registration, payload validation | `src/commands/{index, handlers}.js` | + +--- + +## Related pages + +| Page | Why | +|:---|:---| +| [Home](Home) | Intuitive overview | +| [Reference — Contracts](Reference-Contracts) | Topic + config + child filters | +| [Reference — Examples](Reference-Examples) | Shipped flows + debug recipes | +| [Reference — Limitations](Reference-Limitations) | Known issues and open questions | +| [machineGroupControl wiki](https://gitea.wbd-rd.nl/RnD/machineGroupControl/wiki/Home) | The grouped-control parent: planner, optimizer, rendezvous | +| [EVOLV — Architecture](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Architecture) | Platform-wide three-tier pattern | diff --git a/wiki/Reference-Contracts.md b/wiki/Reference-Contracts.md new file mode 100644 index 0000000..9fbdbe8 --- /dev/null +++ b/wiki/Reference-Contracts.md @@ -0,0 +1,279 @@ +# Reference — Contracts + +![code-ref](https://img.shields.io/badge/code--ref-394a972-blue) + +> [!NOTE] +> Full topic contract, configuration schema, and child-registration filters for `rotatingMachine`. Source of truth: `src/commands/index.js`, `src/specificClass.js` `configure()`, and the schema at `generalFunctions/src/configs/rotatingMachine.json`. +> +> For an intuitive overview, return to the [Home](Home). + +--- + +## Topic contract + +The registry lives in `src/commands/index.js`. Each descriptor maps a canonical `msg.topic` to its handler; aliases emit a one-time deprecation warning the first time they fire. + +| Canonical topic | Aliases | Payload | Unit | Effect | +|:---|:---|:---|:---|:---| +| `set.mode` | `setMode` | `string` (`auto` / `virtualControl` / `fysicalControl`) | — | Switch operational mode. Each mode has its own allow-list of actions and sources. | +| `cmd.startup` | — | any | — | Run the configured `startup` sequence (default `[starting, warmingup, operational]`). | +| `cmd.shutdown` | — | any | — | Run the `shutdown` sequence. If currently `operational`, `executeSequence` first ramps the setpoint to 0 (interruptible). | +| `cmd.estop` | `emergencystop` | any | — | Run the `emergencystop` sequence (default `[emergencystop, off]`). Reachable from every state. | +| `set.setpoint` | `execMovement` | `{setpoint: number}` | control % (no `units` — convert has no `percent` measure) | Move to a control-axis setpoint via `state.moveTo`. | +| `set.flow-setpoint` | `flowMovement` | `{setpoint: number}` or bare number | `volumeFlowRate` (default `m3/h`) | Convert to canonical m³/s, then to control % via `predictCtrl.y`, then `state.moveTo`. | +| `data.simulate-measurement` | `simulateMeasurement` | `{asset: {type, unit}, value, position, childName?, childId?}` | type-specific | Inject a virtual sensor reading. The two virtual children (`dashboard-sim-upstream` / `-downstream`) auto-handle pressure; other types use the registering child's id. | +| `query.curves` | `showWorkingCurves` | any | — | Reply on Port 0 with the current working curves (flow / power / efficiency). | +| `query.cog` | `CoG` | any | — | Reply on Port 0 with the centre-of-gravity (CoG) point. | +| `child.register` | `registerChild` | `string` (child node id) | — | Register a `measurement` child with this machine. Port 2 wiring does this automatically in normal flows. | +| `execSequence` | — | `{action: "startup" \| "shutdown"}` | — | Legacy umbrella: demuxes `payload.action` to the canonical `cmd.startup` / `cmd.shutdown` handler. Marked `_legacy: true`; scheduled for removal. | + +### Mode / source / action allow-lists + +A topic that survives the registry still passes through `flowController.handle`: + +```js +if (!host.isValidActionForMode(action, host.currentMode)) return; +if (!host.isValidSourceForMode(source, host.currentMode)) return; +``` + +Defaults from the schema: + +| Mode | `allowedActions` | `allowedSources` | +|:---|:---|:---| +| `auto` | `statuscheck, execmovement, execsequence, flowmovement, emergencystop, entermaintenance` | `parent, GUI, fysical` | +| `virtualControl` | `statuscheck, execmovement, flowmovement, execsequence, emergencystop, exitmaintenance` | `GUI, fysical` | +| `fysicalControl` | `statuscheck, emergencystop, entermaintenance, exitmaintenance` | `fysical` | + +A rejected request logs at warn and short-circuits; nothing reaches the FSM. + +--- + +## Data model — `getOutput()` shape + +Composed each tick by `src/io/output.js` `buildOutput()`. Delta-compressed: consumers see only the keys that changed. + +### Per-measurement keys + +For every `(type, variant, position)` stored in MeasurementContainer, the flattened output emits: + +``` +... +``` + +Position labels are normalised to lowercase in the keys (`atequipment`, `downstream`, `upstream`, `max`, `min`). The trailing `` is: + +| `` | When | +|:---|:---| +| `default` | The node's own predictions (flow / power / efficiency / Ncog). | +| `dashboard-sim-upstream` / `dashboard-sim-downstream` | The two auto-registered virtual pressure children. | +| The real child's `general.id` | When a registered measurement child wrote the value. | + +Sample keys (operational pump, simulated pressure): + +| Key | Type | Unit | Notes | +|:---|:---|:---|:---| +| `flow.predicted.downstream.default` | number | m³/h | Live predicted flow. | +| `flow.predicted.atequipment.default` | number | m³/h | Same number, equipment-side label. | +| `flow.predicted.max.default` / `.min.default` | number | m³/h | Curve envelope at the current `fDimension`. | +| `power.predicted.atequipment.default` | number | kW | Predicted shaft power. | +| `pressure.measured.upstream.dashboard-sim-upstream` | number | mbar | Last simulated suction pressure. | +| `pressure.measured.downstream.dashboard-sim-downstream` | number | mbar | Last simulated discharge pressure. | +| `temperature.measured.atequipment.dashboard-sim-upstream` | number | °C | Default 15°C until overwritten. | +| `atmPressure.measured.atequipment.dashboard-sim-upstream` | number | Pa | Default 101325 Pa until overwritten. | + +### Scalar keys + +| Key | Type | Source | Notes | +|:---|:---|:---|:---| +| `state` | string | `host.state.getCurrentState()` | One of the FSM states (`idle`, `starting`, `warmingup`, …). | +| `ctrl` | number | `host.state.getCurrentPosition()` | Control-axis position 0..100. | +| `mode` | string | `host.currentMode` | `auto` / `virtualControl` / `fysicalControl`. | +| `runtime` | number | `host.state.getRunTimeHours()` | Cumulative hours in active states. | +| `moveTimeleft` | number | `host.state.getMoveTimeLeft()` | Seconds remaining on the current move (0 when idle). | +| `maintenanceTime` | number | `host.state.getMaintenanceTimeHours()` | Cumulative hours in maintenance. | +| `cog` / `NCog` / `NCogPercent` | number | `host.cog` etc. | CoG metric on the η curve. `NCog` 0..1; `NCogPercent` is `NCog * 100`, rounded to 2 dp. | +| `effDistFromPeak` | number | `host.absDistFromPeak` | Absolute η distance to peak. | +| `effRelDistFromPeak` | number | `host.relDistFromPeak` | Normalised 0..1; `undefined` when η band collapses. | +| `predictionQuality` | string | `host.predictionHealth.quality` | `good` / `warming` / `degraded` / `invalid`. | +| `predictionConfidence` | number | `host.predictionHealth.confidence` | 0..1, rounded to 3 dp. | +| `predictionPressureSource` | string \| null | `host.predictionHealth.pressureSource` | `dashboard-sim` or a real child id; null until pressure landed. | +| `predictionFlags` | array | `host.predictionHealth.flags` | Reason codes (e.g. `pressure_init_warming`). | +| `pressureDriftLevel` | number | `host.pressureDrift.level` | 0..3. | +| `pressureDriftSource` | string \| null | `host.pressureDrift.source` | Source whose drift is worst. | +| `pressureDriftFlags` | array | `host.pressureDrift.flags` | `nominal` when no drift detected. | +| `flowNrmse` / `flowLongTermNRMSD` / `flowImmediateLevel` / `flowLongTermLevel` / `flowDriftValid` | numbers / number / number / boolean | `host.flowDrift` | Only present once `flowDrift != null`. | +| `powerNrmse` / `powerLongTermNRMSD` / `powerImmediateLevel` / `powerLongTermLevel` / `powerDriftValid` | same | `host.powerDrift` | Same. | + +### Status badge + +`buildStatusBadge` in `io/output.js`: + +``` +: % 💨kW +``` + +State symbols (per `STATE_SYMBOLS` map): + +| State | Symbol | Fill | +|:---|:---:|:---| +| `off` | ⬛ | red | +| `idle` | ⏸️ | blue | +| `operational` | ⏵️ | green | +| `starting` | ⏯️ | yellow | +| `warmingup` | 🔄 | green | +| `accelerating` | ⏩ | yellow | +| `decelerating` | ⏪ | yellow | +| `stopping` | ⏹️ | yellow | +| `coolingdown` | ❄️ | yellow | +| `maintenance` | 🔧 | grey | + +Pressure-not-initialised states (`operational`, `warmingup`, `accelerating`, `decelerating`) override the badge to a yellow ring `': pressure not initialized'` until at least one pressure source has been written. + +--- + +## Configuration schema — editor form to config keys + +Source of truth: `generalFunctions/src/configs/rotatingMachine.json` plus `nodeClass.buildDomainConfig`. + +### General (`config.general`) + +| Form field | Config key | Default | Notes | +|:---|:---|:---|:---| +| Name | `general.name` | derived: `_` | Re-derived in `configure()`. | +| (auto-assigned) | `general.id` | `null` | Node-RED node id. | +| Default unit | `general.unit` | `l/s` (schema) / `m3/h` (nodeClass) | `buildDomainConfig` resolves `uiConfig.unit` via `convert` and overrides to a valid flow unit. | +| Enable logging | `general.logging.enabled` | `true` | Master switch. | +| Log level | `general.logging.logLevel` | `info` | `debug` / `info` / `warn` / `error`. | + +### Functionality (`config.functionality`) + +| Form field | Config key | Default | Notes | +|:---|:---|:---|:---| +| Position vs parent | `functionality.positionVsParent` | `atEquipment` | One of `atEquipment` / `upstream` / `downstream`. Used in the child-register payload that goes UP to MGC / pumpingStation. | +| (hidden) | `functionality.softwareType` | `rotatingmachine` | Constant. | +| (hidden) | `functionality.role` | `RotationalDeviceController` | Constant. | +| Distance offset | `functionality.distance` | `null` | Optional spatial offset; populated when `hasDistance` is enabled. | +| Distance unit | `functionality.distanceUnit` | `m` | | +| Distance description | `functionality.distanceDescription` | `""` | Free-text. | + +### Asset (`config.asset`) + +Resolved derived metadata (supplier / category / type / allowed units) lives in `generalFunctions/datasets/assetData/rotatingmachine.json` keyed by `asset.model`. The editor's asset menu reads from that registry. + +| Form field | Config key | Default | Notes | +|:---|:---|:---|:---| +| Asset UUID | `asset.uuid` | `null` | Globally-unique identifier. | +| Tag code | `asset.tagCode` | `null` | | +| Tag number | `asset.tagNumber` | `null` | Legacy column. | +| Geolocation | `asset.geoLocation` | `{x:0, y:0, z:0}` | | +| Model | `asset.model` | `null` | **Required.** Resolves curve + supplier / type / allowed units via the registry. | +| Deployment unit | `asset.unit` | `null` | **Required.** Must be a flow unit; soft-warned if not in the registry's recommended list for the model. | +| Curve units | `asset.curveUnits` | `{pressure:'mbar', flow:'m3/h', power:'kW', control:'%'}` | Carried for curve normalisation. | +| Accuracy | `asset.accuracy` | `null` | Optional sensor accuracy %. | +| (derived) | `asset.machineCurve` | `{nq:{}, np:{}}` | Loaded from `loadModelCurve(model)`, then normalised. | + +> [!WARNING] +> **Legacy fields removed.** `supplier`, `category`, and `assetType` are no longer node config — the registry derives them from the model. Flows saved before the AssetResolver refactor will throw a startup error with a clear migration message. Re-open the node, re-select the model from the asset menu, and save. + +### State times (`stateConfig.time`) + +Set on the state machine via `nodeClass.buildDomainConfig` from editor fields: + +| Form field | Config key | Default (schema) | Notes | +|:---|:---|:---|:---| +| Startup Time | `time.starting` | configured in s | Time spent in `starting` before transitioning to `warmingup`. | +| Warmup Time | `time.warmingup` | configured in s | Time in `warmingup` — **non-interruptible** safety. | +| Shutdown Time | `time.stopping` | configured in s | Time in `stopping`. | +| Cooldown Time | `time.coolingdown` | configured in s | Time in `coolingdown` — **non-interruptible** safety. | + +### Movement (`stateConfig.movement`) + +| Form field | Config key | Default | Notes | +|:---|:---|:---|:---| +| Reaction Speed | `movement.speed` | configured in %/s | Controller ramp rate. E.g. `1` means 1%/s → setpoint 60 from idle reaches 60 in ~60 s. | +| Movement Mode | `movement.mode` | `staticspeed` | `staticspeed` (linear ramp) or `dynspeed` (cubic ease-in-out). Both yield the same total duration; only the curve differs. | +| (internal) | `movement.maxSpeed` | from schema | Hard cap honoured by `movementManager.getNormalizedSpeed`. | +| (internal) | `movement.interval` | from schema | Inner-loop tick of the move animation (ms). | + +### Sequences (`config.sequences`) + +State-transition lists per sequence name. Defaults: + +| Sequence | States | +|:---|:---| +| `startup` | `[starting, warmingup, operational]` | +| `shutdown` | `[stopping, coolingdown, idle]` | +| `emergencystop` | `[emergencystop, off]` | +| `boot` | `[idle, starting, warmingup, operational]` | +| `entermaintenance` | `[stopping, coolingdown, idle, maintenance]` | +| `exitmaintenance` | `[off, idle]` | + +Custom sequences are accepted as long as every step is a known FSM state and the transitions between them are allowed by `stateConfig.allowedTransitions`. + +### Output (`config.output`) + +| Form field | Config key | Default | Range | Notes | +|:---|:---|:---|:---|:---| +| Process Output | `output.process` | `process` | `process` / `json` / `csv` | Port-0 formatter. | +| Database Output | `output.dbase` | `influxdb` | `influxdb` / `json` / `csv` | Port-1 formatter. | + +### Mode (`config.mode`) + +| Form field | Config key | Default | Range | Notes | +|:---|:---|:---|:---|:---| +| Mode | `mode.current` | `auto` | `auto` / `virtualControl` / `fysicalControl` | The active operational mode. | +| (defaults) | `mode.allowedActions.` | see [Architecture](Reference-Architecture#mode--source-allow-lists) | enforced by `flowController.handle` | +| (defaults) | `mode.allowedSources.` | see [Architecture](Reference-Architecture#mode--source-allow-lists) | enforced by `flowController.handle` | + +### Unit policy + +Source: `src/specificClass.js` lines 36–41. + +| Quantity | Canonical (internal) | Output (rendered) | Curve (supplier) | Required-unit | +|:---|:---|:---|:---|:---:| +| Pressure | `Pa` | `mbar` | `mbar` | ✓ | +| Atmospheric pressure | `Pa` | `Pa` | — | ✓ | +| Flow | `m3/s` | `m3/h` | `m3/h` | ✓ | +| Power | `W` | `kW` | `kW` | ✓ | +| Temperature | `K` | `°C` | — | ✓ | +| Control | — | — | `%` | — | + +`requireUnitForTypes` means MeasurementContainer rejects writes that omit `unit` for these types. + +--- + +## Child registration + +Source: `src/measurement/childRegistrar.js` `registerMeasurementChild`. The registrar reads `asset.type` and `positionVsParent` from the child's config and subscribes to `.measured.` on the child's measurement emitter. + +| Software type | Filter | Wired to | Side-effect | +|:---|:---|:---|:---| +| `measurement` | `asset.type='pressure', position=upstream` | `pressureRouter.route('upstream', value, ctx)` | Stored as upstream pressure; refresh prediction + drift. `pressureInitialization` tracks readiness. | +| `measurement` | `asset.type='pressure', position=downstream` | `pressureRouter.route('downstream', value, ctx)` | Same on the discharge side. | +| `measurement` | `asset.type='flow', position=*` | `measurementHandlers.updateMeasuredFlow` | Stored; drift assessed against predicted. | +| `measurement` | `asset.type='power', position=atEquipment` | `measurementHandlers.updateMeasuredPower` | Stored; drift assessed against predicted. | +| `measurement` | `asset.type='temperature', position=*` | `measurementHandlers.updateMeasuredTemperature` | Stored; surfaced on Port 0. | + +### Virtual pressure children — auto-registered + +At startup `specificClass` registers two `measurement`-typed children: + +| Child id | Position | Default value | Use | +|:---|:---|:---|:---| +| `dashboard-sim-upstream` | `upstream` | 0 mbar | Receives `data.simulate-measurement` payloads with position `upstream`. | +| `dashboard-sim-downstream` | `downstream` | 0 mbar | Same for `downstream`. | + +`pressureSelector` prefers a real registered child over the virtuals once one shows up — the virtuals keep listening so dashboards can still inject sim values during real-pressure outages. + +--- + +## Related pages + +| Page | Why | +|:---|:---| +| [Home](Home) | Intuitive overview | +| [Reference — Architecture](Reference-Architecture) | Code map, FSM, prediction + drift pipeline | +| [Reference — Examples](Reference-Examples) | Shipped flows + debug recipes | +| [Reference — Limitations](Reference-Limitations) | Known issues and open questions | +| [EVOLV — Topic Conventions](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions) | Platform-wide topic rules | +| [EVOLV — Telemetry](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Telemetry) | Port 0 / 1 / 2 InfluxDB layout | diff --git a/wiki/Reference-Examples.md b/wiki/Reference-Examples.md new file mode 100644 index 0000000..7be9c45 --- /dev/null +++ b/wiki/Reference-Examples.md @@ -0,0 +1,169 @@ +# Reference — Examples + +![code-ref](https://img.shields.io/badge/code--ref-394a972-blue) + +> [!NOTE] +> Every example flow shipped under `nodes/rotatingMachine/examples/`, plus how to load them, what they show, and the debug recipes that go with them. Live source: `nodes/rotatingMachine/examples/`. + +--- + +## Shipped examples + +| File | Tier | Dependencies | What it shows | +|:---|:---:|:---|:---| +| `01 - Basic Manual Control.json` | 1 | EVOLV only | Single pump driven by inject buttons — mode switching, startup / shutdown / e-stop, control-% and flow-unit setpoints, simulated pressures, maintenance enter / leave. Debug taps on all three ports. | +| `02 - Integration with Machine Group.json` | 2 | EVOLV only | Parent-child demo — one `machineGroupControl` with 2 `rotatingMachine` children. Auto-registration via Port 2 on deploy. Per-pump simulated pressures. | +| `03 - Dashboard Visualization.json` | 3 | EVOLV + `@flowfuse/node-red-dashboard` | FlowFuse charts: flow / power / pressure trends, status panel, per-pump controls. | + +Three legacy files (`basic.flow.json`, `integration.flow.json`, `edge.flow.json`) are kept until the new Tier-2 has been fully Docker-validated; they predate the AssetResolver refactor and may need re-save in the editor before they deploy. + +--- + +## Loading a flow + +### Via the editor + +1. Open the Node-RED editor at `http://localhost:1880`. +2. Menu → Import → drag the JSON file. +3. Click Deploy. + +(The numbered files contain spaces; in the editor's import dialog the filename is purely cosmetic.) + +### Via the Admin API + +```bash +curl -X POST -H 'Content-Type: application/json' \ + --data @"nodes/rotatingMachine/examples/01 - Basic Manual Control.json" \ + http://localhost:1880/flows +``` + +--- + +## Example 01 — Basic Manual Control + +Single-pump flow with one of every input you'd ever send. Validated against a live Node-RED instance (2026-03-05). + +### Nodes on the tab + +| Type | Purpose | +|:---|:---| +| `comment` | Tab header / driver-group labels | +| `inject` × 9 | Mode (auto / virtualControl), startup, shutdown, e-stop, setpoint = 30 / 60 / 100 %, simulated upstream + downstream pressures, simulate flow / power for drift | +| `rotatingMachine` | The unit under test | +| `debug` × 3 | Port 0 (process), Port 1 (telemetry), Port 2 (registration) | + +### What to do after deploy + +1. Click the two pressure simulations (upstream = 0 mbar, downstream = 1100 mbar). Once both land, `predictionPressureSource` flips from `null` to `dashboard-sim` and `predictionFlags` drops the `pressure_init_warming` flag. +2. Click `set.mode = virtualControl` so the GUI source is allowed. +3. Click `cmd.startup`. Watch Port 0 in the debug pane: `state` walks `idle → starting → warmingup → operational`. `runtime` starts accumulating. +4. Click `set.setpoint = 60` (control %). `state` goes `operational → accelerating → operational`; `ctrl` rises from 0 to 60 at the configured `Reaction Speed`. `flow.predicted.downstream.default` and `power.predicted.atequipment.default` update at every position tick. +5. Click `set.flow-setpoint = {value: 80, unit: 'm3/h'}` — same path, but the setpoint is a flow value; the node converts via `predictCtrl` to a control %. +6. Click `cmd.shutdown`. State: `operational → decelerating → stopping → coolingdown → idle`. The ramp-to-zero step is interruptible; the subsequent transitions are timed by `time.stopping` and `time.coolingdown`. + +> [!IMPORTANT] +> **GIF needed.** Demo recording of steps 1–6 + the status badge progression. Save as `wiki/_partial-gifs/rotatingMachine/01-basic-demo.gif`, target ≤ 1 MB after `gifsicle -O3 --lossy=80`. + +### Try the residue handler + +After the pump reaches `operational` at 60 %: + +1. Send `set.setpoint = 20`. `state` goes `operational → decelerating → …`. +2. While `decelerating`, send `set.setpoint = 80`. +3. `state.moveTo` sees the residue, transitions back to `operational` synchronously, then ramps up to 80. No setpoint is lost. + +This is the same mechanism the MGC planner relies on for fast retargets. + +### Try the sequence-abort token + +After the pump reaches `operational` at 60 %, simulate the Scenario-5 race: + +1. Send `cmd.shutdown`. The pump begins ramping to zero. +2. *Within the ramp window*, send `set.setpoint = 60`. The new setpoint's residue-handler claims the FSM back to `operational`. +3. Watch the log: instead of the shutdown's for-loop continuing through `stopping → coolingdown → idle`, you'll see `Sequence 'shutdown' interrupted during ramp-down by external abort; not entering shutdown loop.` + +Without the token (pre-2026-05-15), the pump would have ended at `idle` despite the new setpoint — with `delayedMove = 60` sitting unused. + +--- + +## Example 02 — Integration with Machine Group + +> [!IMPORTANT] +> **Screenshot needed.** Editor capture of `02 - Integration with Machine Group.json`. Save as `wiki/_partial-screenshots/rotatingMachine/02-integration.png`. Replace this callout with the image link. + +One MGC + two rotatingMachine children. Demonstrates: + +- Auto-registration via Port 2 at deploy (each pump's `child.register` reaches the MGC; no manual wiring needed). +- Independent per-pump controls (the injects still target each pump's input by id). +- Group-level aggregation: MGC's Port 0 sums the children's predicted flow + power into the group aggregate. + +The MGC planner is exercised when MGC's `set.demand` fires (not in this example by default; add an inject if you want to see it). + +--- + +## Example 03 — Dashboard Visualization + +> [!IMPORTANT] +> **Screenshots needed.** Two captures: the editor tab and the rendered dashboard. Save as `wiki/_partial-screenshots/rotatingMachine/03-dashboard-editor.png` and `04-dashboard-rendered.png`. + +A single pump on a FlowFuse Dashboard 2.0 page with: + +- Control buttons (mode, startup, shutdown, e-stop) +- A setpoint slider +- Live status (state badge, ctrl%, predicted flow / power / efficiency) +- Trend charts: flow, power, pressure, drift level + +Required: `@flowfuse/node-red-dashboard` installed in the Node-RED instance. + +--- + +## Docker compose snippet + +To bring up Node-RED + InfluxDB with EVOLV nodes pre-loaded: + +```yaml +# docker-compose.yml (extract) +services: + nodered: + build: ./docker/nodered + ports: ['1880:1880'] + volumes: + - ./docker/nodered/data:/data/evolv + influxdb: + image: influxdb:2.7 + ports: ['8086:8086'] +``` + +Full file: [EVOLV/docker-compose.yml](https://gitea.wbd-rd.nl/RnD/EVOLV/src/branch/development/docker-compose.yml). + +--- + +## Debug recipes + +| Symptom | First thing to check | Where to look | +|:---|:---|:---| +| Editor throws `legacy asset field(s) [supplier]` on deploy | Flow predates the AssetResolver refactor. Re-open the node, pick the model from the asset menu, save. The registry derives supplier / category / type. | `src/nodeClass.js` `_rejectLegacyAssetFields`. | +| `state` stuck on `idle` after `cmd.startup` | The action isn't allowed for this mode / source combination. Check `flowController` warn log for ` is not allowed in mode ` or ` is not allowed in mode `. | `_setupState`, `isValidSourceForMode`, `isValidActionForMode`. | +| `flow.predicted.*` reads `0` or `NaN` | Pressure hasn't initialised. `predictionFlags` will include `pressure_init_warming`. Inject pressure via `data.simulate-measurement` or wire real measurement children. | `getMeasuredPressure` + `pressureSelector`. | +| `predictionQuality: 'invalid'` from startup | Curve normalisation failed — null predictors installed. Look for `Curve normalization failed for model …` in the log. The asset / model is unrecognised, the unit isn't a flow unit, or the registry entry is missing. | `_setupCurves`. | +| Drift level stays at `3` after startup | Fewer than `minSamplesForLongTerm = 10` paired samples have landed. Wait ~10 ticks; the level falls automatically. | `driftProfiles.minSamplesForLongTerm`. | +| `cmd.estop` and then the pump won't restart | Allowed transitions out of `emergencystop` are `idle` / `off` / `maintenance`. Send `cmd.shutdown` to drop into `idle`, then `cmd.startup`. | `stateConfig.allowedTransitions.emergencystop`. | +| Position bounces near the target | `dynspeed` (cubic ease-in-out) can overshoot at high speed. Try `staticspeed` (linear). Both modes have the same total duration. | `movement.mode`. | +| Pump still drifts to `idle` after a mid-shutdown re-engage | Verify the submodule is at `394a972` or newer — the sequence-abort token in `state.js` + `sequenceController.js` is what closes that race. | `state.sequenceAbortToken`. | +| `data.simulate-measurement` payloads aren't reflected on Port 0 | Payload shape: `{asset: {type: 'pressure', unit: 'mbar'}, value: 1100, position: 'downstream', childId: 'dashboard-sim-downstream'}`. Missing `asset.type` or `position` gets a `Unsupported simulateMeasurement type:` warn and is dropped. | `measurementHandlers.updateSimulatedMeasurement`. | +| Per-pump Port 0 key names differ from what your dashboard expects | rotatingMachine uses `...` (e.g. `flow.predicted.downstream.default`). MGC uses `__`. Don't mix them. | `io/output.js`, `MeasurementContainer.getFlattenedOutput`. | + +> Never ship `enableLog: 'debug'` in a demo — fills the container log within seconds and obscures real errors. + +--- + +## Related pages + +| Page | Why | +|:---|:---| +| [Home](Home) | Intuitive overview | +| [Reference — Contracts](Reference-Contracts) | Topic + config + child filters | +| [Reference — Architecture](Reference-Architecture) | Code map, FSM, prediction + drift pipeline | +| [Reference — Limitations](Reference-Limitations) | Known issues and open questions | +| [machineGroupControl — Examples](https://gitea.wbd-rd.nl/RnD/machineGroupControl/wiki/Reference-Examples) | Group-control demo flows | +| [EVOLV — Topology Patterns](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topology-Patterns) | Where rotatingMachine fits in a larger plant | diff --git a/wiki/Reference-Limitations.md b/wiki/Reference-Limitations.md new file mode 100644 index 0000000..27f38b8 --- /dev/null +++ b/wiki/Reference-Limitations.md @@ -0,0 +1,105 @@ +# Reference — Limitations + +![code-ref](https://img.shields.io/badge/code--ref-394a972-blue) + +> [!NOTE] +> What `rotatingMachine` does not do, current rough edges, and open questions. Open items live in `.agents/improvements/IMPROVEMENTS_BACKLOG.md` in the superproject. + +--- + +## When you would not use this node + +| Scenario | Use instead | +|:---|:---| +| A passive non-return / check valve (no motor) | `valve` — no curve, no FSM-driven motor. | +| A valve actuator (motorised, no characteristic curve) | `valve` (and `valveGroupControl` if grouped). | +| A group of 2 + pumps load-sharing on a header | `machineGroupControl` — instantiate this as a child. | +| A curve-less asset | Predictions degrade to zero, drift becomes meaningless, status badge falls into `predictionQuality: 'invalid'`. There is no fallback model. | +| A compressor with significant gas compressibility | Predictor uses an incompressible-flow curve; output is qualitatively right but quantitatively biased. Tracked. | + +--- + +## Known limitations + +### Single-side pressure degrades silently + +`pressureSelector.getMeasuredPressure` accepts only-upstream or only-downstream readings as a fallback when the differential is unknown. It logs a warn (`Using downstream pressure only for prediction: …. Prediction accuracy is degraded; inject upstream pressure too.`) but proceeds. The predictor uses the absolute pressure as a surrogate differential, which can materially bias flow predictions under varying suction conditions. The warn is one-shot per state transition, not per tick — it can be missed in long-running deployments. Tracked. + +### Multi-parent registration + +`childRegistrationUtils` accepts registration under multiple parents. The pump emits child-register messages to each, and parents listen in parallel. Teardown ordering (parent gone first vs pump gone first) is not test-covered; observed behaviour in production is "fine, mostly". If you wire one pump to two MGCs and remove one MGC mid-deployment, the pump's listener set may keep a stale reference. Open question. + +### `data.simulate-measurement` doesn't clear stale values + +If you toggle a virtual pressure off (stop sending the inject), the last-known value persists in the MeasurementContainer. There is no TTL and no explicit clear topic. Workaround: send `value: null` or `0` explicitly. Tracked. + +### `execSequence` legacy umbrella + +The `execSequence` topic (with `payload.action = "startup" | "shutdown"`) is kept alive for legacy flows. The handler demuxes to the canonical topic; both emit a one-time deprecation warning. Scheduled for removal in a later phase. Use `cmd.startup` / `cmd.shutdown` instead. + +### Drift confidence collapses on long pressure-source outages + +`predictionHealth.refresh` reduces `predictionConfidence` to 0 when no pressure source has produced a reading in > 30 s. The quality string flips to `invalid` — downstream consumers should treat this as "predictor is offline, ignore values" rather than "predictor is broken". The recovery is automatic: as soon as a pressure measurement lands, health climbs back. Open question whether to model this as a discrete "stale" quality state instead. + +### `state` stays in residue after a routine abort + +`abortCurrentMovement` with default options (the kind MGC fires) does **not** auto-transition the FSM back to `operational`. The pump stays parked in `accelerating` / `decelerating` until the next `moveTo` arrives — at which point the residue handler in `state.moveTo` runs the transition synchronously. By design (a previous version auto-transitioned and created a bounce loop where every tick aborted, returned, re-moved, aborted again). See the comment in `state.js` `moveTo` line 76 for the historical detail. + +### Editor cosmetics don't reflect `asset` derivation + +The editor form still has visual sections for supplier / category / type even though the registry derives them. They're read-only and informational; some fields render as blank until you select a model. Cosmetic; the registry is the source of truth. + +--- + +## Open questions (tracked) + +| Question | Where it lives | +|:---|:---| +| Should the predictor use an explicit "stale" quality state instead of collapsing to `invalid` when pressure data dries up? | Internal — not yet ticketed | +| Multi-parent teardown ordering | Internal | +| Add an explicit `data.clear-simulated-measurement` topic for sim cleanup | Internal | +| Compressor / gas-flow curve handling | Internal (long-term) | +| Phase 7 removal of `execSequence` umbrella + legacy aliases | Internal | +| Curve loader robustness: warn / refuse mismatched curve units instead of best-effort normalising | `OPEN_QUESTIONS.md` (rotatingMachine entry) | + +--- + +## Migration notes + +### From pre-AssetResolver + +Old flows saved with `supplier`, `category`, or `assetType` fields will throw on deploy: + +``` +rotatingMachine: legacy asset field(s) [supplier, category] are saved on this node. +After the AssetResolver refactor these are derived from the model id. +Open the node in the editor, re-select the model, and save to migrate. +``` + +The fix is mechanical: open each rotatingMachine node, re-pick the model from the asset menu, save. No data is lost — the registry has the same supplier / category / type the old flow carried. + +### From pre-sequence-abort-token + +Before 2026-05-15 a mid-decel re-engage was a race — sometimes the shutdown's for-loop won and parked the pump at `idle` with an orphaned `delayedMove`. With the `sequenceAbortToken` mechanism in `state.js` + `sequenceController.js` (from `394a972` onward), the new-dispatch's `abortCurrentMovement` always wins: the shutdown's for-loop breaks out before its next transition. + +If you have an integration test that relied on the older "shutdown always completes" behaviour, expect to see `Sequence 'shutdown' interrupted ... by external abort` warnings instead. That's the intended new state. + +### From `setpoint` topic name (pre-canonical) + +The old `setpoint` topic without a `set.` prefix has been retired. Use `set.setpoint` (alias `execMovement`) for control-% setpoints and `set.flow-setpoint` (alias `flowMovement`) for flow setpoints. + +### From `execMovement` payload shape change + +Legacy payloads were `{source, action: "execMovement", setpoint: number}`. The current shape is the same minus `action` (the handler dispatches via topic). Both are accepted. + +--- + +## Related pages + +| Page | Why | +|:---|:---| +| [Home](Home) | Intuitive overview | +| [Reference — Contracts](Reference-Contracts) | Topic + config + child filters (alias map at the end) | +| [Reference — Architecture](Reference-Architecture) | Code map, FSM (including sequence-abort token), prediction + drift | +| [Reference — Examples](Reference-Examples) | Shipped flows + debug recipes | +| [machineGroupControl — Limitations](https://gitea.wbd-rd.nl/RnD/machineGroupControl/wiki/Reference-Limitations) | Where the parent's planner currently bypasses priority mode | diff --git a/wiki/_Sidebar.md b/wiki/_Sidebar.md new file mode 100644 index 0000000..6df5641 --- /dev/null +++ b/wiki/_Sidebar.md @@ -0,0 +1,19 @@ +### rotatingMachine + +- [Home](Home) + +**Reference** + +- [Contracts](Reference-Contracts) +- [Architecture](Reference-Architecture) +- [Examples](Reference-Examples) +- [Limitations](Reference-Limitations) + +**Related** + +- [EVOLV master wiki](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Home) +- [machineGroupControl wiki](https://gitea.wbd-rd.nl/RnD/machineGroupControl/wiki/Home) +- [pumpingStation wiki](https://gitea.wbd-rd.nl/RnD/pumpingStation/wiki/Home) +- [Topology Patterns](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topology-Patterns) +- [Topic Conventions](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Topic-Conventions) +- [Telemetry](https://gitea.wbd-rd.nl/RnD/EVOLV/wiki/Telemetry)