B1.4: cooldown-guard ROOT CAUSE — schema strip of constraint keys
Root cause: configUtils.initConfig was silently stripping the four unknown constraint keys (nominalFlowMin, flowMax, maxRainRef, minSampleIntervalSec) because they weren't declared in the schema. With those keys gone, validateFlowBounds saw NaN/NaN and routed every i_start into the invalid-bounds branch — _beginRun never fired, so sumPuls stayed 0. Fix is in generalFunctions/src/configs/monster.json (declared the four keys with sensible defaults). Plus a 4-line comment at the guard site documenting the schema dependency. 10/10 tests pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -17,6 +17,10 @@ function applyBoundsAndTargets(m) {
|
||||
}
|
||||
|
||||
function validateFlowBounds(m) {
|
||||
// nominalFlowMin / flowMax must be declared in monster.json's `constraints`
|
||||
// section. If they aren't, configUtils strips them as unknown keys and the
|
||||
// bounds collapse to undefined → NaN → invalid here, which silently blocks
|
||||
// every sampling run. (Fixed 2026-05-11.)
|
||||
const min = Number(m.nominalFlowMin);
|
||||
const max = Number(m.flowMax);
|
||||
const valid = Number.isFinite(min) && Number.isFinite(max) && min >= 0 && max > 0 && min < max;
|
||||
|
||||
Reference in New Issue