fn_chart_pump_a/b/c now emit -1 on the ctrl output when the cached pump state is off/idle/maintenance, instead of the residual ctrl% (which would sit at 0 and be indistinguishable from a pump genuinely running at 0%). ui_chart_pumps_ctrl ymin set to -5 so the OFF rail is visible below the 0-100 band. Adds test/integration/per-pump-ctrl-fanout.integration.test.js covering both chart outputs of all three pumps in populated (running), OFF (off/idle/maintenance), and degraded (missing state/ctrl/flow, pre-tick, NaN, ctrl-only delta) states per .claude/rules/output-coverage.md. Updates test/_output-manifest.md to document the previously-undocumented per-pump fan-out functions. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>