@@ -115,8 +115,8 @@ async function equalFlowControl(ctx, Qd, _powerCap = Infinity, priorityList = nu
|
||||
}
|
||||
}
|
||||
|
||||
const fUnit = mgc._unitView.canonical.power;
|
||||
const flUnit = mgc._unitView.canonical.flow;
|
||||
const fUnit = mgc.unitPolicy.canonical.power;
|
||||
const flUnit = mgc.unitPolicy.canonical.flow;
|
||||
mgc.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, totalPower, fUnit);
|
||||
mgc.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, totalFlow, flUnit);
|
||||
mgc.measurements.type('efficiency').variant('predicted').position(POSITIONS.AT_EQUIPMENT).value(totalFlow / totalPower);
|
||||
@@ -189,16 +189,16 @@ async function prioPercentageControl(ctx, input, priorityList = null) {
|
||||
const totalPower = [];
|
||||
const totalFlow = [];
|
||||
Object.values(mgc.machines).forEach(machine => {
|
||||
const p = mgc.operatingPoint.readChild(machine, 'power', 'predicted', POSITIONS.AT_EQUIPMENT, mgc._unitView.canonical.power);
|
||||
const f = mgc.operatingPoint.readChild(machine, 'flow', 'predicted', POSITIONS.DOWNSTREAM, mgc._unitView.canonical.flow);
|
||||
const p = mgc.operatingPoint.readChild(machine, 'power', 'predicted', POSITIONS.AT_EQUIPMENT, mgc.unitPolicy.canonical.power);
|
||||
const f = mgc.operatingPoint.readChild(machine, 'flow', 'predicted', POSITIONS.DOWNSTREAM, mgc.unitPolicy.canonical.flow);
|
||||
if (p !== null) totalPower.push(p);
|
||||
if (f !== null) totalFlow.push(f);
|
||||
});
|
||||
|
||||
const sumP = totalPower.reduce((a, b) => a + b, 0);
|
||||
const sumF = totalFlow.reduce((a, b) => a + b, 0);
|
||||
mgc.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, sumP, mgc._unitView.canonical.power);
|
||||
mgc.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, sumF, mgc._unitView.canonical.flow);
|
||||
mgc.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, sumP, mgc.unitPolicy.canonical.power);
|
||||
mgc.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, sumF, mgc.unitPolicy.canonical.flow);
|
||||
if (sumP > 0) {
|
||||
mgc.measurements.type('efficiency').variant('predicted').position(POSITIONS.AT_EQUIPMENT).value(sumF / sumP);
|
||||
}
|
||||
|
||||
@@ -7,22 +7,22 @@
|
||||
|
||||
const { statusBadge, POSITIONS } = require('generalFunctions');
|
||||
|
||||
function _outputUnitForType(unitView, type) {
|
||||
function _outputUnitForType(unitPolicy, type) {
|
||||
switch (String(type || '').toLowerCase()) {
|
||||
case 'flow': return unitView.output.flow;
|
||||
case 'power': return unitView.output.power;
|
||||
case 'pressure': return unitView.output.pressure;
|
||||
case 'temperature': return unitView.output.temperature;
|
||||
case 'flow': return unitPolicy.output.flow;
|
||||
case 'power': return unitPolicy.output.power;
|
||||
case 'pressure': return unitPolicy.output.pressure;
|
||||
case 'temperature': return unitPolicy.output.temperature;
|
||||
default: return null;
|
||||
}
|
||||
}
|
||||
|
||||
function getOutput(mgc) {
|
||||
const out = {};
|
||||
const { measurements, _unitView, mode, scaling, absDistFromPeak, relDistFromPeak } = mgc;
|
||||
const { measurements, unitPolicy, mode, scaling, absDistFromPeak, relDistFromPeak } = mgc;
|
||||
measurements.getTypes().forEach(type => {
|
||||
measurements.getVariants(type).forEach(variant => {
|
||||
const unit = _outputUnitForType(_unitView, type);
|
||||
const unit = _outputUnitForType(unitPolicy, type);
|
||||
const read = (pos) => measurements.type(type).variant(variant).position(pos).getCurrentValue(unit || undefined);
|
||||
const dn = read(POSITIONS.DOWNSTREAM);
|
||||
const at = read(POSITIONS.AT_EQUIPMENT);
|
||||
@@ -46,9 +46,9 @@ function getOutput(mgc) {
|
||||
|
||||
function getStatusBadge(mgc) {
|
||||
const totalFlow = mgc.measurements.type('flow').variant('predicted').position(POSITIONS.AT_EQUIPMENT)
|
||||
.getCurrentValue(mgc._unitView.output.flow) ?? 0;
|
||||
.getCurrentValue(mgc.unitPolicy.output.flow) ?? 0;
|
||||
const totalPower = mgc.measurements.type('power').variant('predicted').position(POSITIONS.AT_EQUIPMENT)
|
||||
.getCurrentValue(mgc._unitView.output.power) ?? 0;
|
||||
.getCurrentValue(mgc.unitPolicy.output.power) ?? 0;
|
||||
const totalCapacity = mgc.dynamicTotals?.flow?.max ?? 0;
|
||||
const available = Object.values(mgc.machines).filter(m => {
|
||||
const s = m?.state?.getCurrentState?.();
|
||||
|
||||
@@ -36,24 +36,6 @@ class MachineGroup extends BaseDomain {
|
||||
// tests still write directly (matches the pumpingStation pattern).
|
||||
this.machines = {};
|
||||
|
||||
// groupOps/totals/optimizer modules expect the legacy object-style
|
||||
// policy (ctx.unitPolicy.canonical.flow). UnitPolicy on BaseDomain
|
||||
// exposes canonical()/output() methods, so build a compatible view.
|
||||
this._unitView = Object.freeze({
|
||||
canonical: Object.freeze({
|
||||
flow: this.unitPolicy.canonical('flow'),
|
||||
pressure: this.unitPolicy.canonical('pressure'),
|
||||
power: this.unitPolicy.canonical('power'),
|
||||
temperature: this.unitPolicy.canonical('temperature'),
|
||||
}),
|
||||
output: Object.freeze({
|
||||
flow: this.unitPolicy.output('flow'),
|
||||
pressure: this.unitPolicy.output('pressure'),
|
||||
power: this.unitPolicy.output('power'),
|
||||
temperature: this.unitPolicy.output('temperature'),
|
||||
}),
|
||||
});
|
||||
|
||||
this.scaling = this.config.scaling.current;
|
||||
this.mode = this.config.mode.current;
|
||||
this.absDistFromPeak = 0;
|
||||
@@ -71,12 +53,12 @@ class MachineGroup extends BaseDomain {
|
||||
this.operatingPoint = new GroupOperatingPoint({
|
||||
measurements: this.measurements,
|
||||
machines: this.machines,
|
||||
unitPolicy: this._unitView,
|
||||
unitPolicy: this.unitPolicy,
|
||||
logger: this.logger,
|
||||
});
|
||||
this.totals = new TotalsCalculator({
|
||||
machines: this.machines,
|
||||
unitPolicy: this._unitView,
|
||||
unitPolicy: this.unitPolicy,
|
||||
logger: this.logger,
|
||||
operatingPoint: this.operatingPoint,
|
||||
isMachineActive: (id) => this.isMachineActive(id),
|
||||
@@ -165,8 +147,8 @@ class MachineGroup extends BaseDomain {
|
||||
handlePressureChange() {
|
||||
this.operatingPoint.equalize();
|
||||
const totals = this.calcDynamicTotals();
|
||||
const fUnit = this._unitView.canonical.flow;
|
||||
const pUnit = this._unitView.canonical.power;
|
||||
const fUnit = this.unitPolicy.canonical.flow;
|
||||
const pUnit = this.unitPolicy.canonical.power;
|
||||
this.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, totals.flow.act, fUnit);
|
||||
// Mirror live aggregate onto DOWNSTREAM — PS subscribes here for the
|
||||
// outflow signal. See preserve-tests/ps-mgc-flow-contract regression.
|
||||
@@ -227,8 +209,8 @@ class MachineGroup extends BaseDomain {
|
||||
}
|
||||
|
||||
// INTENT lands on AT_EQUIPMENT only; DOWNSTREAM is the live aggregate.
|
||||
this.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, bestResult.bestPower, this._unitView.canonical.power);
|
||||
this.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, bestResult.bestFlow, this._unitView.canonical.flow);
|
||||
this.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, bestResult.bestPower, this.unitPolicy.canonical.power);
|
||||
this.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, bestResult.bestFlow, this.unitPolicy.canonical.flow);
|
||||
this.measurements.type('efficiency').variant('predicted').position(POSITIONS.AT_EQUIPMENT).value(bestResult.bestFlow / bestResult.bestPower);
|
||||
this.measurements.type('Ncog').variant('predicted').position(POSITIONS.AT_EQUIPMENT).value(bestResult.bestCog);
|
||||
|
||||
@@ -314,8 +296,8 @@ class MachineGroup extends BaseDomain {
|
||||
finally { this._shutdownInFlight.delete(id); }
|
||||
}
|
||||
}));
|
||||
const fUnit = this._unitView.canonical.flow;
|
||||
const pUnit = this._unitView.canonical.power;
|
||||
const fUnit = this.unitPolicy.canonical.flow;
|
||||
const pUnit = this.unitPolicy.canonical.power;
|
||||
this.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.DOWNSTREAM, 0, fUnit);
|
||||
this.operatingPoint.writeOwn('flow', 'predicted', POSITIONS.AT_EQUIPMENT, 0, fUnit);
|
||||
this.operatingPoint.writeOwn('power', 'predicted', POSITIONS.AT_EQUIPMENT, 0, pUnit);
|
||||
@@ -323,8 +305,8 @@ class MachineGroup extends BaseDomain {
|
||||
}
|
||||
|
||||
_canonicalToOutputFlow(value) {
|
||||
const from = this._unitView.canonical.flow;
|
||||
const to = this._unitView.output.flow;
|
||||
const from = this.unitPolicy.canonical.flow;
|
||||
const to = this.unitPolicy.output.flow;
|
||||
if (!from || !to || from === to) return value;
|
||||
return convert(value).from(from).to(to);
|
||||
}
|
||||
|
||||