Files
EVOLV/wiki/Glossary.md
znetsixe 5ae8788fd7 wiki: crisp overhaul — no decoration emoji, all 9 master pages refactored
Source-tree mirror of EVOLV.wiki.git refactor (27a42ee on wiki.git):

- 7 master pages rewritten with clean design (Home, Architecture,
  Topology-Patterns, Topic-Conventions, Telemetry, Getting-Started,
  Glossary). Tables and Mermaid for visuals, gitea alert callouts for
  warnings, shields badges for metadata only. No emoji as decoration.
- Archive.md becomes a removal-changelog pointing readers to git
  history and to the successor pages.
- _Sidebar.md updated to navigate the new flat-name layout.
- Concept / finding / manual pages: uniform mini-header (badges +
  "reference page" callout) added without rewriting domain content.
- Every internal link now uses the flat naming that resolves on the
  live gitea wiki (Concept-ASM-Models, Finding-BEP-..., etc.).

On wiki.git: 29 Archive-* pages hard-deleted (the git history
preserves them; Archive.md documents the removal).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-11 22:24:51 +02:00

7.1 KiB
Raw Permalink Blame History

Glossary

code-ref

Note

S88, EVOLV runtime, wastewater, pump / hydraulics, control, and project terms. Use this page as a dictionary while reading the other wiki pages.


S88 — ISA-88 batch control

flowchart TB
    enterprise["Enterprise"]
    site["Site"]
    area["Area"]
    pc["Process Cell"]
    unit["Unit"]
    em["Equipment Module"]
    cm["Control Module"]

    enterprise --> site --> area --> pc --> unit --> em --> cm

    class enterprise,site neutral
    class area area
    class pc pc
    class unit unit
    class em equip
    class cm ctrl

    classDef neutral fill:#dddddd
    classDef area fill:#0f52a5,color:#fff
    classDef pc fill:#0c99d9,color:#fff
    classDef unit fill:#50a8d9,color:#000
    classDef equip fill:#86bbdd,color:#000
    classDef ctrl fill:#a9daee,color:#000
Term Meaning in EVOLV
Area Plant section. Reserved — no node implements it yet
Process Cell (PC) Self-contained sub-process. pumpingStation is the only PC-level node
Unit (UN) One major piece of equipment or a coordinator. MGC, VGC, reactor, settler, monster
Equipment Module (EM) A single piece of equipment. rotatingMachine, valve, diffuser
Control Module (CM) A single sensor or actuator. measurement
softwareType The node's S88 type. Used by ChildRouter to match child.register

EVOLV runtime

Term Meaning
BaseDomain Base class for every specificClass. Owns measurements, router, emitter, logger
BaseNodeAdapter Base class for every nodeClass. Bridges Node-RED to specificClass via commandRegistry
specificClass Pure-JS domain logic. No RED.* imports. Unit-testable in isolation
nodeClass Node-RED adapter — input routing, tick loop, port wiring, status badge
ChildRouter Declarative matcher for child.register. router.onRegister(swType, handler)
commandRegistry Inbound-msg dispatcher. Topic to descriptor; resolves aliases, coerces units
UnitPolicy Per-node declaration of canonical (internal) and output units
MeasurementContainer Chainable measurement store. Keys: <type>.<variant>.<position>.<childId>
statusBadge Composes node.status({fill, shape, text}) from a HealthStatus
HealthStatus {level: 0..3, flags, message, source} — standardised health summary
LatestWinsGate Mutex with supersede semantics. Superseded calls resolve with {superseded: true}
outputUtils Port-0 delta compression and Port-1 line-protocol formatting
tick 1 Hz update loop. Opt-in via static tickInterval = N on nodeClass
'output-changed' Event the specificClass fires on this.emitter when public state shifts
getOutput() Domain method returning the current snapshot — fed to outputUtils
getFlattenedOutput() Measurements with dot-flattened keys (4-segment type.variant.position.childId)

Topic prefixes

See Topic Conventions for the full reference.

Prefix Direction Idempotent
set. in Yes
cmd. in No (side-effects)
data. in / out n/a
query. in Yes (read-only)
child. in (parent) Yes (id-keyed)
evt. out n/a

Wastewater treatment terms

Term Meaning
WWTP Wastewater Treatment Plant
Influent / Effluent Inlet / outlet stream of a process unit
Activated Sludge Biological process — bacteria consume organic matter under aeration. Modelled by ASM1, ASM3
MLSS Mixed Liquor Suspended Solids — biomass concentration in the reactor
RAS Return Activated Sludge — settled sludge pumped back from settler to reactor
WAS Waste Activated Sludge — excess sludge removed from the system
TSS Total Suspended Solids
COD / BOD Chemical / Biological Oxygen Demand — organic load metrics
NH4 / NO3 Ammonium / Nitrate — N species, key for nitrification / denitrification
DO Dissolved Oxygen (mg/L). Setpoint typically around 2 mg/L in aerated zones
K_La Volumetric mass-transfer coefficient (oxygen transfer rate / driving force)
OTR Oxygen Transfer Rate — diffuser's output to the reactor
HRT / SRT Hydraulic / Sludge Retention Time
F/M ratio Food-to-microorganism ratio
Composite sample A sample built over time, often flow-proportional — what monster simulates

See ASM Models for biological kinetics in detail.


Pump / hydraulics terms

Term Meaning
BEP Best Efficiency Point — operating point with minimum energy per unit flow
NPSH Net Positive Suction Head — pressure margin to avoid cavitation
Affinity laws Q proportional N, H proportional N-squared, P proportional N-cubed — how flow / head / power scale with pump speed
Characteristic curve Q to H (or Q to P, Q to efficiency) graph supplied by the pump manufacturer
NCog Normalised cost-of-going metric used by MGC for switching stability
Wet-well basin Buffer volume on a lift station — what pumpingStation models
Setpoint Commanded value (e.g. flow setpoint = 12 m3/h)
Demand Integrated requirement (e.g. parent's "need this much flow now")

See Pump Affinity Laws and BEP Gravitation Proof.


Control / signal-processing terms

Term Meaning
PID Proportional-Integral-Derivative controller
Anti-windup Prevents the integral term from growing unboundedly when the actuator saturates
Hysteresis Switching threshold with a deadband (e.g. start at 80%, stop at 30%)
Schmitt trigger Hysteresis-based binary switch (used for stopLevel in pumpingStation)
Smoothing Filtering noise (moving average, exponential, Savitzky-Golay)
Outlier detection Identifying readings outside expected variance
FSM Finite State Machine — discrete states + transitions

See PID Control Theory and Signal Processing — Sensors.


Project terms

Term Meaning
Tier 14 Refactor phases. See Home Refactor status
Wave A / B / C Sub-batches of submodule pointer bumps during the refactor
OPEN_QUESTIONS.md Live decisions log at .claude/refactor/OPEN_QUESTIONS.md
CONTRACTS.md API shapes at .claude/refactor/CONTRACTS.md
MODULE_SPLIT.md Per-node concern layout at .claude/refactor/MODULE_SPLIT.md
CONVENTIONS.md Code style and naming at .claude/refactor/CONVENTIONS.md
WIKI_TEMPLATE.md Per-node 14-section template at .claude/refactor/WIKI_TEMPLATE.md
AUTOGEN block Sections regenerated by npm run wiki:all. Do not hand-edit between markers

Page Why
Home Top-level node map
Architecture Runtime concepts in context
Topic Conventions Full topic / unit / colour reference
Topology Patterns Terms used in plant scenarios