fix: fully configure PS basin + add node-completeness rule
Some checks failed
CI / lint-and-test (push) Has been cancelled
Some checks failed
CI / lint-and-test (push) Has been cancelled
Basin undersized (10m³) for sinus peak (126 m³/h) → overflow → 122%. Now 30 m³ with 4m height, all PS fields set. New rule: always configure every field of every node. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -240,7 +240,20 @@ If you only fill the top-level fields, `payload_type=json` is silently treated a
|
||||
|
||||
Both ends store the paired ids in `links`. The `name` is cosmetic (label only) — Node-RED routes by id. Multiple emitters can target one receiver; one emitter can target multiple receivers.
|
||||
|
||||
## 9. Verifying the layout
|
||||
## 9. Node configuration completeness — ALWAYS set every field
|
||||
|
||||
When placing an EVOLV node in a flow (demo or production), configure **every config field** the node's schema defines — don't rely on schema defaults for operational parameters. Schema defaults exist to make the validator happy, not to represent a realistic plant.
|
||||
|
||||
**Why this matters:** A pumpingStation with `basinVolume: 10` but default `heightOverflow: 2.5` and default `heightOutlet: 0.2` creates an internally inconsistent basin where the fill % exceeds 100%, safety guards fire at wrong thresholds, and the demo looks broken. Every field interacts with every other field.
|
||||
|
||||
**The rule:**
|
||||
1. Read the node's config schema (`generalFunctions/src/configs/<nodeName>.json`) before writing the flow.
|
||||
2. For each section (basin, hydraulics, control, safety, scaling, smoothing, …), set EVERY field explicitly in the flow JSON — even if you'd pick the same value as the default.
|
||||
3. Add a comment in the flow generator per section explaining WHY you chose each value (e.g. "basin sized so sinus peak takes 6 min to fill from startLevel to overflow").
|
||||
4. Cross-check computed values: `surfaceArea = volume / height`, `maxVolOverflow = heightOverflow × surfaceArea`, gauge `max` = basin `height`, fill % denominator = `volume` (not overflow volume).
|
||||
5. If a gauge or chart references a config value (basin height, maxVol), derive it from the same source — never hardcode a number that was computed elsewhere.
|
||||
|
||||
## 10. Verifying the layout
|
||||
|
||||
Before declaring a flow done:
|
||||
|
||||
|
||||
Reference in New Issue